Catalog item

CAPACITOR,FIXED,ELECTROLYTIC

5910FSC
01NCB code
214-8485Item number
NIIN 01-214-8485
Request a quote
Unit price
$63.00
Unit of issue
EA
Source of supply
NRP
DEMIL code
A

Identification

Item name code
00008
PINC
0000008
Criticality code
Y
II
0
DEMIL code
A
NIIN assigned
16-AUG-85
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8532290040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DNDNRPEA0.0000$63.001U0M1HX3BL9$0.00I
01-OCT-2026DNDNRPEA0.0000$63.001U0M1HX3BL9$0.00N

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
634L504-1524374
BECHTEL TECHNICAL SERVICES INC MACHINERY APPARATUS OPN
H59CHXB
MIL-C-396581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41GHX
7N64 PC 11402750
EATON AEROSPACE LLC DBA EATON INOAC DIV FLUID & ELECTRICAL DISTRIBUTION
A51CHX
7N78PC9106RP6
DRS NAVAL POWER SYSTEMS INC DBA DRS POWER & CONTROL TECHNOLOGIES INC
A51CHX
7N74PC2006RP6
DRS NAVAL POWER SYSTEMS INC DBA DRS POWER & CONTROL TECHNOLOGIES INC
A51CHX
L0345216236
DLA WEAPONS SUPPORT (COLUMBUS) DBA DLA VENDOR ITEM DRAWING (VID) DIV DOCUMENT STANDARDIZATION DIVISION (VA)
A32CHX

Characteristics

BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES NOMINAL 0.364
BODY LENGTHINCHES NOMINAL 1.275
BODY WIDTHINCHES NOMINAL 0.783
BODY HEIGHTINCHES NOMINAL 2.500
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.624
SCHEMATIC DIAGRAM DESIGNATOR
ANODE TYPEETCHED FOIL
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS7.2
ELECTRICAL POLARIZATIONPOLARIZED
FEATURES PROVIDEDHERMETICALLY SEALED CASE
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 550.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0
DC LEAKAGE AT MAXIMUM OPERATING TEMPMICROAMPERES 770.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 75.0
CRITICALITY CODE JUSTIFICATIONFEAT
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -15.00 TO 75.00
CAPACITIVE ELECTRODE MATERIALTANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT20.0000
DC LEAKAGE AT REFERENCE TEMPMICROAMPERES 96.000
TERMINAL SURFACE TREATMENTSOLDER
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE ELECTRONICS SUPPLY CENTER PRODUCTION STANDARD NO. L03452; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 2

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOAAuth collabSupp collab
YA01YA01-JUL-01YA81YA
ZW01ZW01-DEC-05ZW81ZW
N1HEDN1T01-APR-91PHXHX06HXGG

Service data

Navy

COG
1H
SMIC
X3
IRRC
BL
SMCC
9

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
ZZZZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
Z
Special requirements - See specific instructions or drawings provided.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
Z
Special requirements – See specific instructions or drawings provided
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
A

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
UCL
O
Unit container is not an acceptable shipping container.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
Q
Unit pack weight
0.1000
UP SZ MAXB
4.00000
UP SZ MAXL
6.00000
UP SZ MAXH
0.50000
Unit pack cube
0.0070
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
ZZ = PACKAGE, CLEAN AND MARK PER IRPOD

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
16-AUG-1985
NIIN status code
0

Request a quote