Catalog item

CAPACITOR,FIXED,ELECTROLYTIC

5910FSC
01NCB code
237-8413Item number
NIIN 01-237-8413
Request a quote
Unit price
$1,240.99
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00008
PINC
0000008
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
07-AUG-86
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8532290040
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$1,240.991U0ZQ2200X-$0.00A
01-OCT-2026DSJSMSEA0.0000$1,240.991U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
MIL-C-39018/781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TXB
MIL-PRF-39018/781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
M39018/07-0221M81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.000
TERMINAL LENGTHINCHES NOMINAL 2.500
BODY DIAMETERINCHES MAXIMUM 0.910
BODY LENGTHINCHES MINIMUM 3.125 AND INCHES MAXIMUM 3.343
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETERINCHES NOMINAL 0.300
TERMINAL DIAMETERINCHES NOMINAL 0.040
SCHEMATIC DIAGRAM DESIGNATOR
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS0.035
ELECTRICAL POLARIZATIONPOLARIZED
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 7500.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 105.0
DC LEAKAGE AT MAXIMUM OPERATING TEMPMICROAMPERES 710.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 7.5
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -10.00 TO 75.00
CAPACITIVE ELECTRODE MATERIALALUMINUM
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS0.047
DC LEAKAGE AT REFERENCE TEMPMICROAMPERES 119.000
TERMINAL SURFACE TREATMENTSOLDER
CASE INSULATION MATERIALPLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39018
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 4
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39018 TO 7

MOE rules

MOE rule
A918
MOE CD
DA
AMC
1
AMSC
T
Date assigned
01-JUN-06
IMC
Z
IMCA
CD
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
98001

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
TX
Dt stdzn dec
01-FEB-1998
NIIN status code
0

Cancelled and replaced NIINs

FSC
5910
Cancelled NIIN
5910-01-039-8988
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.