Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
00NCB code
009-9975Item number
NIIN 00-009-9975
Request a quote
Unit price
$4,384.36
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00765
PINC
0000765
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
11-AUG-72
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
Y
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$4,384.36
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
6091051-103640
LOCKHEED MARTIN CORPORATION DIV ROTARY AND MISSION SYSTEMS
A321TX3D
10B576-113058
SORA POWER INC. DBA SORA POWER INC
A595TX3B
6091051-113058
SORA POWER INC. DBA SORA POWER INC
A595TX3B

Characteristics

INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEVOLTS AT SEA LEVEL 200.0
UNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 3.000
SPECIAL FEATURES7 FUNCTIONS
OPERATING CURRENT RATING PER FUNCTION IN AMPSSIXTH FUNCTION 6TH RADIO INTERFERENCE 0.25
OPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 1.1
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
INPUT TERMINAL MANUFACTURER CODE71468
INPUT TERMINAL IDENTIFICATIONDPGM21-34PB
MAXIMUM TEMP RISECELSIUS 25.0
SOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
STYLE DESIGNATOR
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 120.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSIXTH FUNCTION VOLTS DC 6TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 120.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
OVERALL LENGTHINCHES NOMINAL 4.120
OVERALL HEIGHTINCHES NOMINAL 5.245
OVERALL WIDTHINCHES MAXIMUM 2.620
MOUNTING SLOT WIDTHINCHES NOMINAL 0.160
BODY LENGTHINCHES NOMINAL 3.000
BODY WIDTHINCHES NOMINAL 2.120
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.375
VIBRATION RESISTANCE RANGE IN HERTZ5.0 TO 1500.0
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.500
OPERATING TEMP RANGECELSIUS -54.0 TO 125.0
AVERAGE LIFE RATING IN HOURS5000.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
MOUNTING FACILITY TYPE AND QUANTITYFIRST FUNCTION SLOT 3
MOUNTING FACILITY TYPE AND QUANTITYSECOND FUNCTION THREADED HOLE(S) 4
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 400.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIFTH FUNCTION 5TH RADIO INTERFERENCE 0.05
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 1.1
OPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 0.5
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 1.1
NOMINAL THREAD SIZEINCHES 0.138
BODY MATERIALMETAL
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 120.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS DC 4TH RADIO INTERFERENCE 28.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION THREADED STUD OUTPUT 7
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION THREADED STUD GROUND 1
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
1
AMSC
G
Date assigned
01-JUN-06
PICA
GX
PICA LOA
01
Auth collab
GX
Supp collab
TX
Fmr MOE rl
DTX1

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.