Catalog item

FILTER,BAND PASS

5915FSC
00NCB code
140-1304Item number
NIIN 00-140-1304
Request a quote
Unit price
$688.80
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
27-APR-74
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$688.801U0AQ2200X-$0.00A
01-OCT-2026DSJSMSEA0.0000$688.801U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
SM-A-742459-380063
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
A321TX1D
A742459-304655
GENERAL DYNAMICS MISSION SYSTEMS, INC.
A525TX1D
SM-A-742459-308715
CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC
A595TX1B

Characteristics

INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIFTH FUNCTION 5TH BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 3.0
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONFIFTH FUNCTION KILOHERTZ 5TH BAND PASS 2.55 AND KILOHERTZ 5TH BAND PASS 2.65
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 922.00 AND HERTZ 1ST BAND PASS 959.00
FREQUENCY BAND WIDTH PER FUNCTIONFOURTH FUNCTION KILOHERTZ 4TH BAND PASS 2.21 AND KILOHERTZ 4TH BAND PASS 2.30
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 1.19 AND KILOHERTZ 2ND BAND PASS 1.23
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND PASS 1.45 AND KILOHERTZ 3RD BAND PASS 1.51
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIFTH FUNCTION MINIMUM 5TH BAND PASS 3.0 AND MAXIMUM 5TH BAND PASS 30.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 3.0 AND MAXIMUM 1ST BAND PASS 30.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFOURTH FUNCTION MINIMUM 4TH BAND PASS 3.0 AND MAXIMUM 4TH BAND PASS 30.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 3.0 AND MAXIMUM 2ND BAND PASS 30.0
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED PIN(S) 15
OVERALL HEIGHTINCHES MAXIMUM 0.700
BODY LENGTHINCHES MAXIMUM 4.030
BODY WIDTHINCHES MAXIMUM 2.280
BODY HEIGHTINCHES MAXIMUM 0.510
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 3.500
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 800.0
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.750
OPERATING TEMP RANGECELSIUS -18.0 TO 75.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFOURTH FUNCTION 4TH BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND PASS 3.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 2
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 5
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN GROUND 1
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIFTH FUNCTION KILOHERTZ 5TH BAND PASS 2.52 AND KILOHERTZ 5TH BAND PASS 2.55 AND KILOHERTZ 5TH BAND PASS 2.65 AND KILOHERTZ 5TH BAND PASS 2.68
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 913.00 AND HERTZ 1ST BAND PASS 922.00 AND HERTZ 1ST BAND PASS 959.00 AND HERTZ 1ST BAND PASS 970.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFOURTH FUNCTION KILOHERTZ 4TH BAND PASS 2.18 AND KILOHERTZ 4TH BAND PASS 2.21 AND KILOHERTZ 4TH BAND PASS 2.30 AND KILOHERTZ 4TH BAND PASS 2.32
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 1.17 AND KILOHERTZ 2ND BAND PASS 1.19 AND KILOHERTZ 2ND BAND PASS 1.23 AND KILOHERTZ 2ND BAND PASS 1.25
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND PASS 1.43 AND KILOHERTZ 3RD BAND PASS 1.45 AND KILOHERTZ 3RD BAND PASS 1.51 AND KILOHERTZ 3RD BAND PASS 1.52
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION KILOHMS 3RD BAND PASS 1.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION KILOHMS 5TH BAND PASS 100.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION KILOHMS 1ST BAND PASS 100.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION KILOHMS 4TH BAND PASS 100.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION KILOHMS 2ND BAND PASS 100.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION KILOHMS 3RD BAND PASS 100.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH BAND PASS
REFERENCE FREQUENCY PER FUNCTIONFIFTH FUNCTION KILOHERTZ 5TH BAND PASS 2.6
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 941.0
REFERENCE FREQUENCY PER FUNCTIONFOURTH FUNCTION KILOHERTZ 4TH BAND PASS 2.25
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 1.21
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND PASS 1.48
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION KILOHMS 5TH BAND PASS 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION KILOHMS 1ST BAND PASS 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION KILOHMS 4TH BAND PASS 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION KILOHMS 2ND BAND PASS 1.0
BODY SURFACE TREATMENTTIN
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ4.000
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD BAND PASS
INCLOSURE TYPEHERMETICALLY SEALED
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND PASS 3.0 AND MAXIMUM 3RD BAND PASS 30.0
STYLE DESIGNATOR

MOE rules

MOE rule
A918
MOE CD
DA
AMC
1
AMSC
G
Date assigned
01-JUN-06
IMC
Z
IMCA
CD
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Supp collab
CL
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
CL
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.6000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0090
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.