Catalog item

FILTER,BAND PASS

5915FSC
00NCB code
377-5883Item number
NIIN 00-377-5883
Request a quote
Unit price
$53.02
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
J
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$53.02
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
40033608241
LOCKHEED MARTIN CORP LOCKHEED MARTIN MISSION SYSTEMS
H595TX1D
40033610001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
A321TX1D

Characteristics

LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION KILOHMS 1ST BAND PASS 10.0
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 85.00 AND HERTZ 1ST BAND PASS 145.00
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 88.00 AND HERTZ 2ND BAND PASS 145.00
INCLOSURE TYPEENCASED
STYLE DESIGNATOR
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION KILOHMS 2ND BAND PASS 10.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION KILOHMS 1ST BAND PASS 10.0
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED STUD(S) 4
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 2.0
OVERALL HEIGHTINCHES MAXIMUM 4.375
BODY LENGTHINCHES MAXIMUM 6.375
BODY WIDTHINCHES MAXIMUM 3.750
BODY HEIGHTINCHES NOMINAL 3.000
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.062
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 2.062
OPERATING TEMP RANGECELSIUS -55.0 TO 85.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 115.0
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 115.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION KILOHMS 1ST BAND PASS 10.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION SOLDER STUD OUTPUT 2
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM BLANK 32.0 AND MAXIMUM BLANK 2.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 1.00 AND HERTZ BLANK 85.00 AND HERTZ BLANK 145.00 AND HERTZ BLANK 230.00
NOMINAL THREAD SIZEINCHES 0.164
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION SOLDER STUD GROUND 1
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION SOLDER STUD INPUT 2
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 2.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collab
ZR01ZR01-JUL-97ZR81ZR
DGX1DS0001-NOV-25GX01GX

Freight

ACTY CD
XX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
FA
MIL-P-130, laminated and creped wrapping paper
Cush dun
BG
A-A-1898, Grade II, water resistant cellulosic cushioning
THK
C
3/4 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
TX
Dt stdzn dec
06-SEP-1971
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.