Catalog item

FILTER,BAND PASS

5915FSC
00NCB code
921-4502Item number
NIIN 00-921-4502
Request a quote
Unit price
$790.78
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
11-DEC-65
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$790.781U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$790.781U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
CC0107-0132840
CONOLOG CORPORATION DBA INIVEN
A525TX
CC0107-132840
CONOLOG CORPORATION DBA INIVEN
A595TXB
A671-156662
FREQUENCY SELECTIVE NETWORKS, INC. DBA FREQUENCY SELECTIVE NETWORKS INC
A525TX
21-0521-0199480
BUNDY ELECTRONICS DIV OF COVINGTON CORP
H595TX3B
262413-101534
RAYTHEON COMPANY DBA RAYTHEON CO
A321TX3D
ML10685109376
OMNITEC DATA CORP SUB OF NYTRONICS INC
H595TX3B

Characteristics

MOUNTING FACILITY TYPE AND QUANTITYFIRST FUNCTION THREADED STUD(S) 2
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 382.50 AND HERTZ 3RD BAND PASS 403.75 AND HERTZ 3RD BAND PASS 446.25 AND HERTZ 3RD BAND PASS 467.50
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 3.0 AND MAXIMUM 2ND BAND PASS 30.0
NOMINAL THREAD SIZEINCHES 0.138
BODY MATERIALMETAL
MOUNTING FACILITY TYPE AND QUANTITYSECOND FUNCTION THREADED HOLE(S) 4
OVERALL HEIGHTINCHES NOMINAL 3.230
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 403.75 AND HERTZ 3RD BAND PASS 446.25
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEVOLTS AT SEA LEVEL 500.0
SPECIAL FEATURESELECTROSTATIC SHIELD BROUGHT OUT TO TERMINAL SIX
STYLE DESIGNATOR
FEATURES PROVIDEDELECTROSTATIC SHIELD
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 600.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 600.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 600.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD BAND PASS
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
BODY LENGTHINCHES NOMINAL 3.000
BODY WIDTHINCHES MAXIMUM 1.410
BODY HEIGHTINCHES NOMINAL 2.950
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION TURRET OUTPUT 3
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION TURRET GROUND 1
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 382.50 AND HERTZ 1ST BAND PASS 403.75 AND HERTZ 1ST BAND PASS 446.25 AND HERTZ 1ST BAND PASS 467.50
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 382.50 AND HERTZ 2ND BAND PASS 403.75 AND HERTZ 2ND BAND PASS 446.25 AND HERTZ 2ND BAND PASS 467.50
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 600.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 600.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 3.0 AND MAXIMUM 1ST BAND PASS 30.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 600.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND PASS 3.0 AND MAXIMUM 3RD BAND PASS 30.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 403.75 AND HERTZ 1ST BAND PASS 446.25
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 403.75 AND HERTZ 2ND BAND PASS 446.25
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND PASS 3.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION TURRET INPUT 2
INCLOSURE TYPEHERMETICALLY SEALED
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
OPERATING TEMP RANGECELSIUS -55.0 TO 65.0
AVERAGE LIFE RATING IN HOURS10000.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 425.0
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 425.0
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 425.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YB01YB01-APR-91YB81YB
N9BNDN1G01-JUN-06ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
HH
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
93008

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
13-AUG-1971
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.