Catalog item

FILTER,BAND PASS

5915FSC
00NCB code
924-1887Item number
NIIN 00-924-1887
Request a quote
Unit price
$93.01
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
20-JAN-66
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
X
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$93.01
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
15825-193928
DYCO ELECTRONICS INC
HC16ZZAC
362-7562-111530
LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN INFORMATION SYSTEMS & GLOBAL SOLUTIONS
A392TU1D

Characteristics

STYLE DESIGNATOR
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION WIRE LEAD GROUND 1
OPERATING TEMP RANGECELSIUS -20.0 TO 80.0
OVERALL HEIGHTINCHES MAXIMUM 0.400
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION WIRE LEAD OUTPUT 2
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 200.00 AND HERTZ 2ND BAND PASS 332.00
BODY HEIGHTINCHES NOMINAL 0.775
REFERENCE FREQUENCY PER FUNCTIONFIFTH FUNCTION HERTZ 5TH BAND PASS 266.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 266.0
REFERENCE FREQUENCY PER FUNCTIONFOURTH FUNCTION HERTZ 4TH BAND PASS 266.0
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 200.00 AND HERTZ 3RD BAND PASS 332.00
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 266.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 45.0 AND MAXIMUM 1ST BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFOURTH FUNCTION MINIMUM 4TH BAND PASS 45.0 AND MAXIMUM 4TH BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 45.0 AND MAXIMUM 2ND BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND PASS 45.0 AND MAXIMUM 3RD BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIFTH FUNCTION 5TH BAND PASS 5.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 5.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIFTH FUNCTION HERTZ 5TH BAND PASS 150.00 AND HERTZ 5TH BAND PASS 200.00 AND HERTZ 5TH BAND PASS 332.00 AND HERTZ 5TH BAND PASS 392.00
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTTHIRD FUNCTION KILOHMS 3RD BAND PASS 10.0
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED TERMINAL 5
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 5.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND PASS 5.0
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 266.0
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTFOURTH FUNCTION KILOHMS 4TH BAND PASS 10.0
INPUT IMPEDANCE PER FUNCTION W/LOADFIFTH FUNCTION KILOHMS 5TH BAND PASS 4.0
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONFIFTH FUNCTION HERTZ 5TH BAND PASS 200.00 AND HERTZ 5TH BAND PASS 332.00
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 200.00 AND HERTZ 1ST BAND PASS 332.00
FREQUENCY BAND WIDTH PER FUNCTIONFOURTH FUNCTION HERTZ 4TH BAND PASS 200.00 AND HERTZ 4TH BAND PASS 332.00
INPUT IMPEDANCE PER FUNCTION W/LOADFOURTH FUNCTION KILOHMS 4TH BAND PASS 4.0
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTSECOND FUNCTION KILOHMS 2ND BAND PASS 10.0
INPUT IMPEDANCE PER FUNCTION W/LOADTHIRD FUNCTION KILOHMS 3RD BAND PASS 4.0
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTFIFTH FUNCTION KILOHMS 5TH BAND PASS 10.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIFTH FUNCTION MINIMUM 5TH BAND PASS 45.0 AND MAXIMUM 5TH BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFOURTH FUNCTION 4TH BAND PASS 5.0
BODY LENGTHINCHES MAXIMUM 2.000
BODY WIDTHINCHES MAXIMUM 1.750
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 150.00 AND HERTZ 1ST BAND PASS 200.00 AND HERTZ 1ST BAND PASS 332.00 AND HERTZ 1ST BAND PASS 392.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFOURTH FUNCTION HERTZ 4TH BAND PASS 150.00 AND HERTZ 4TH BAND PASS 200.00 AND HERTZ 4TH BAND PASS 332.00 AND HERTZ 4TH BAND PASS 392.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 150.00 AND HERTZ 2ND BAND PASS 200.00 AND HERTZ 2ND BAND PASS 332.00 AND HERTZ 2ND BAND PASS 392.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 150.00 AND HERTZ 3RD BAND PASS 200.00 AND HERTZ 3RD BAND PASS 332.00 AND HERTZ 3RD BAND PASS 392.00
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION WIRE LEAD INPUT 2
INPUT IMPEDANCE PER FUNCTION W/LOADFIRST FUNCTION KILOHMS 1ST BAND PASS 4.0
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTFIRST FUNCTION KILOHMS 1ST BAND PASS 10.0
INPUT IMPEDANCE PER FUNCTION W/LOADSECOND FUNCTION KILOHMS 2ND BAND PASS 4.0

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
0
AMSC
0
Date assigned
01-NOV-25
PICA
GX
PICA LOA
01
Auth collab
GX

Freight

ACTY CD
SG
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
13-AUG-1971
NIIN status code
0

Request a quote