Catalog item

FILTER,BAND PASS

5915FSC
00NCB code
925-9980Item number
NIIN 00-925-9980
Request a quote
Unit price
$79.59
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
11-FEB-66
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
X
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$79.59
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part number
362-7562-6
CAGE
11530
LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN INFORMATION SYSTEMS & GLOBAL SOLUTIONS
CAGE status
A
RNCC
3
RNVC
9
Document availability code
2
RNAAC
TU
RNFC
1
RNSC
D

Characteristics

OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTFOURTH FUNCTION KILOHMS 4TH BAND PASS 10.0
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED TERMINAL 5
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIFTH FUNCTION 5TH BAND PASS 5.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 5.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFOURTH FUNCTION 4TH BAND PASS 5.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 5.0
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTSECOND FUNCTION KILOHMS 2ND BAND PASS 10.0
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTTHIRD FUNCTION KILOHMS 3RD BAND PASS 10.0
BODY LENGTHINCHES MAXIMUM 2.000
BODY WIDTHINCHES MAXIMUM 1.750
BODY HEIGHTINCHES NOMINAL 0.775
REFERENCE FREQUENCY PER FUNCTIONFIFTH FUNCTION HERTZ 5TH BAND PASS 926.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 926.0
REFERENCE FREQUENCY PER FUNCTIONFOURTH FUNCTION HERTZ 4TH BAND PASS 926.0
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTFIFTH FUNCTION KILOHMS 5TH BAND PASS 10.0
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTFIRST FUNCTION KILOHMS 1ST BAND PASS 10.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 45.0 AND MAXIMUM 1ST BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFOURTH FUNCTION MINIMUM 4TH BAND PASS 45.0 AND MAXIMUM 4TH BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 45.0 AND MAXIMUM 2ND BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND PASS 45.0 AND MAXIMUM 3RD BAND PASS 3.0
STYLE DESIGNATOR
FREQUENCY BAND WIDTH PER FUNCTIONFOURTH FUNCTION HERTZ 4TH BAND PASS 860.00 AND HERTZ 4TH BAND PASS 992.00
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 860.00 AND HERTZ 2ND BAND PASS 992.00
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND PASS 5.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION TAB, SOLDER LUG INPUT 2
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION TAB, SOLDER LUG OUTPUT 2
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIFTH FUNCTION HERTZ 5TH BAND PASS 791.00 AND HERTZ 5TH BAND PASS 860.00 AND HERTZ 5TH BAND PASS 992.00 AND KILOHERTZ 5TH BAND PASS 1.06
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 926.0
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 926.0
INPUT IMPEDANCE PER FUNCTION W/LOADFIFTH FUNCTION KILOHMS 5TH BAND PASS 4.0
INPUT IMPEDANCE PER FUNCTION W/LOADFIRST FUNCTION KILOHMS 1ST BAND PASS 4.0
INPUT IMPEDANCE PER FUNCTION W/LOADFOURTH FUNCTION KILOHMS 4TH BAND PASS 4.0
INPUT IMPEDANCE PER FUNCTION W/LOADSECOND FUNCTION KILOHMS 2ND BAND PASS 4.0
INPUT IMPEDANCE PER FUNCTION W/LOADTHIRD FUNCTION KILOHMS 3RD BAND PASS 4.0
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 860.00 AND HERTZ 3RD BAND PASS 992.00
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIFTH FUNCTION MINIMUM 5TH BAND PASS 45.0 AND MAXIMUM 5TH BAND PASS 3.0
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 860.00 AND HERTZ 1ST BAND PASS 992.00
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONFIFTH FUNCTION HERTZ 5TH BAND PASS 860.00 AND HERTZ 5TH BAND PASS 992.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 791.00 AND HERTZ 3RD BAND PASS 860.00 AND HERTZ 3RD BAND PASS 992.00 AND KILOHERTZ 3RD BAND PASS 1.06
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 791.00 AND HERTZ 2ND BAND PASS 860.00 AND HERTZ 2ND BAND PASS 992.00 AND KILOHERTZ 2ND BAND PASS 1.06
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFOURTH FUNCTION HERTZ 4TH BAND PASS 791.00 AND HERTZ 4TH BAND PASS 860.00 AND HERTZ 4TH BAND PASS 992.00 AND KILOHERTZ 4TH BAND PASS 1.06
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 791.00 AND HERTZ 1ST BAND PASS 860.00 AND HERTZ 1ST BAND PASS 992.00 AND KILOHERTZ 1ST BAND PASS 1.06

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
0
AMSC
0
Date assigned
01-NOV-25
PICA
GX
PICA LOA
01
Auth collab
GX

Freight

ACTY CD
SG
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
DA
A-A-1249, paper, tissue
Cush dun
BG
A-A-1898, Grade II, water resistant cellulosic cushioning
THK
C
3/4 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
13-AUG-1971
NIIN status code
0

Request a quote