Catalog item

FILTER,BAND PASS

5915FSC
00NCB code
926-0107Item number
NIIN 00-926-0107
Request a quote
Unit price
$1,122.62
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
07-MAR-66
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DSYSMSEA0.0000$1,122.621U0-------$0.00I
01-OCT-2026GPYSMSEA0.0000$1,122.621U0-------$0.00C

Part numbers

Part number
327-221
CAGE
90073
CMC ELECTRONICS INC
CAGE status
A
RNCC
3
RNVC
2
Document availability code
1
RNAAC
TX
RNFC
3
RNSC
D

Characteristics

BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 1.00 AND KILOHERTZ 1ST BAND PASS 10.00
BODY WIDTHINCHES NOMINAL 0.625
BODY HEIGHTINCHES MAXIMUM 0.487
OPERATING TEMP RANGECELSIUS -55.0 TO 85.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 5.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 2
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 40.00 AND KILOHERTZ 2ND BAND PASS 1.00 AND KILOHERTZ 2ND BAND PASS 10.00 AND GIGAHERTZ 2ND BAND PASS 3.30
OVERALL HEIGHTINCHES NOMINAL 0.580
BODY LENGTHINCHES NOMINAL 0.625
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 2
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN GROUND 1
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 40.00 AND KILOHERTZ 1ST BAND PASS 1.00 AND KILOHERTZ 1ST BAND PASS 10.00 AND GIGAHERTZ 1ST BAND PASS 3.30
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 3.0
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 1.00 AND KILOHERTZ 2ND BAND PASS 10.00
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 3.0 AND MAXIMUM 1ST BAND PASS 35.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 3.0 AND MAXIMUM 2ND BAND PASS 35.0
STYLE DESIGNATOR
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED TERMINAL 5
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 5.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 430.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 1ST BAND PASS 430.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 100.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 100.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
YB01YB01-APR-91YB81YB
ZC01ZC01-APR-91ZC81ZC
C911GP3A01-JUN-06GX01XG5DXG GXC007

Freight

ACTY CD
CL
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
FA
MIL-P-130, laminated and creped wrapping paper
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
92338

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
13-AUG-1971
NIIN status code
0

Request a quote