Catalog item

FILTER,LOW PASS

5915FSC
00NCB code
938-2634Item number
NIIN 00-938-2634
Request a quote
Unit price
$843.93
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
13911
PINC
0013911
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
27-FEB-70
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNXSMSEA0.0000$843.931U09B-----$0.00N
01-OCT-2026DSXSMSEA0.0000$843.931U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
546-27496341
COBHAM ADVANCED ELECTRONIC SOLUTIONS INC.
H591ZZ
5214-800096341
COBHAM ADVANCED ELECTRONIC SOLUTIONS INC.
H595ZZB
546-27400779
TE CONNECTIVITY CORPORATION
A321ZZ
546-27411556
M/A-COM INC
R591HH3B

Characteristics

BODY HEIGHTINCHES MAXIMUM 0.406
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN GROUND 1
BODY OUTSIDE DIAMETERINCHES MAXIMUM 0.375
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 1
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 2
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED TERMINAL 4
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST LOW PASS 0.5
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND LOW PASS 0.5
VOLTAGE STANDING WAVE RATIO PER FUNCTIONFIRST FUNCTION 1ST LOW PASS 1.3
VOLTAGE STANDING WAVE RATIO PER FUNCTIONSECOND FUNCTION 2ND LOW PASS 1.5
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND LOW PASS 1.00 AND MEGAHERTZ 2ND LOW PASS 70.00 AND MEGAHERTZ 2ND LOW PASS 104.50 AND MEGAHERTZ 2ND LOW PASS 139.00
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST LOW PASS 2.00 AND MEGAHERTZ 1ST LOW PASS 32.00
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND LOW PASS 1.00 AND MEGAHERTZ 2ND LOW PASS 70.00
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST LOW PASS 3.0 AND MAXIMUM 1ST LOW PASS 40.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MAXIMUM 2ND LOW PASS 3.0 AND MAXIMUM 2ND LOW PASS 40.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST LOW PASS 2.0 AND MEGAHERTZ 1ST LOW PASS 32.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND LOW PASS 1.0 AND MEGAHERTZ 2ND LOW PASS 70.0
OPERATING TEMP RANGECELSIUS -55.0 TO 85.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST LOW PASS 32.0
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND LOW PASS 70.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST LOW PASS 75.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND LOW PASS 75.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST LOW PASS 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND LOW PASS 50.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST LOW PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND LOW PASS
STYLE DESIGNATOR

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZC01ZC01-APR-91ZC81ZC
N9BNDN1L01-JUN-06ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
HH
NMFC
069100
NMFC sub
Z
Uniform freight class
21275
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
FILTERS:CARTRIDGES/ELEMENTS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0090
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
16139

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
10-APR-1979
NIIN status code
0

Request a quote