Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
01NCB code
013-7248Item number
NIIN 01-013-7248
Request a quote
Unit price
$2,042.81
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00765
PINC
0000765
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
07-DEC-75
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$2,042.811709B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$2,042.81170-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
519640-164547
HONEYWELL INTERNATIONAL, INC
A321TX
519640-170210
HONEYWELL INTERNATIONAL INC.
A32BTX1D
RF0923713619
EMS DEVELOPMENT CORPORATION DBA EMS DEVELOPMENT CORP
A525ZZ
RF923713619
EMS DEVELOPMENT CORPORATION DBA EMS DEVELOPMENT CORP
A59AZZ

Characteristics

OVERALL LENGTHINCHES MAXIMUM 3.630
OVERALL HEIGHTINCHES MAXIMUM 1.350
BODY LENGTHINCHES MAXIMUM 3.330
BODY WIDTHINCHES MAXIMUM 2.830
BODY HEIGHTINCHES MAXIMUM 1.350
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.800
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 2.300
OPERATING TEMP RANGECELSIUS -55.0 TO 85.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION KILOHMS 5TH RADIO INTERFERENCE 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION KILOHMS 6TH RADIO INTERFERENCE 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION KILOHMS 4TH RADIO INTERFERENCE 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION KILOHMS 2ND RADIO INTERFERENCE 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION KILOHMS 3RD RADIO INTERFERENCE 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION KILOHMS 1ST RADIO INTERFERENCE 1.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION KILOHMS 2ND RADIO INTERFERENCE 1.0
LOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION KILOHMS 6TH RADIO INTERFERENCE 1.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION KILOHMS 5TH RADIO INTERFERENCE 1.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION KILOHMS 4TH RADIO INTERFERENCE 1.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION KILOHMS 3RD RADIO INTERFERENCE 1.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION KILOHMS 1ST RADIO INTERFERENCE 1.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIFTH FUNCTION 5TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSIXTH FUNCTION 6TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFOURTH FUNCTION 4TH RADIO INTERFERENCE 400.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 16.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSIXTH FUNCTION 6TH RADIO INTERFERENCE 1.5
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 16.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 1.5
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIFTH FUNCTION 5TH RADIO INTERFERENCE 16.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 16.0
MAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 1.3
MAXIMUM VOLTAGE DROP PER FUNCTIONSIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 1.3
MAXIMUM VOLTAGE DROP PER FUNCTIONFIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 1.3
MAXIMUM VOLTAGE DROP PER FUNCTIONFOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 1.3
MAXIMUM VOLTAGE DROP PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 1.3
MAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.3
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
INPUT TERMINAL MANUFACTURER CODE70210
INPUT TERMINAL IDENTIFICATION394-007-9002
OUTPUT TERMINAL MANUFACTURER CODE70210
OUTPUT TERMINAL IDENTIFICATION394-007-9002
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 4
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION WIRE HOOK OUTPUT 6
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION WIRE HOOK INPUT 6
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 115.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 115.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 115.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 115.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 115.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 115.0
NOMINAL THREAD SIZEINCHES 0.138
BODY MATERIALMETAL
SPECIAL FEATURES3.130 IN. W MAX INCL TERMINALS
PROPRIETARY CHARACTERISTICSPACS
STYLE DESIGNATOR

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
1
AMSC
P
Date assigned
01-JUN-06
IMC
Z
IMCA
KE
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
KE GT
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
EA
MIL-DTL-17667, neutral wrapping paper
Cush dun
BG
A-A-1898, Grade II, water resistant cellulosic cushioning
THK
C
3/4 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
1.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0370
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
23-AUG-1989
NIIN status code
0