Catalog item
Request a quoteFILTER,BAND PASS
5915FSC
01NCB code
015-8306Item number
NIIN 01-015-8306
- Unit price
- $1,294.04
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00209
- PINC
- 0000209
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 29-JAN-76
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- Schedule B export code
- 8527995030
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DA | X | SMS | EA | 0.0000 | $1,294.04 | 1 | U | 0 | Z | Q22RHX- | $0.00 | A |
| 01-OCT-2026 | DS | X | SMS | EA | 0.0000 | $1,294.04 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| SM-A-742459-1 | 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR | A | 3 | 2 | 1 | TX | 1 | D |
| A742459-1 | 04655 GENERAL DYNAMICS MISSION SYSTEMS, INC. | A | 5 | 2 | 5 | TX | 1 | D |
| SM-A-742459-1 | 08715 CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC | A | 5 | 9 | 5 | TX | 1 | B |
Characteristics
| OVERALL HEIGHT | INCHES MAXIMUM 0.700 |
|---|---|
| BODY LENGTH | INCHES MAXIMUM 4.030 |
| BODY WIDTH | INCHES MAXIMUM 2.380 |
| BODY HEIGHT | INCHES MAXIMUM 0.510 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 3.500 |
| VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 1.750 |
| OPERATING TEMP RANGE | CELSIUS -18.0 TO 75.0 |
| AVERAGE LIFE RATING IN HOURS | 26280.0 |
| REFERENCE FREQUENCY PER FUNCTION | FIFTH FUNCTION HERTZ 5TH BAND PASS 570.0 |
| REFERENCE FREQUENCY PER FUNCTION | SECOND FUNCTION HERTZ 2ND BAND PASS 770.0 |
| REFERENCE FREQUENCY PER FUNCTION | THIRD FUNCTION HERTZ 3RD BAND PASS 852.0 |
| REFERENCE FREQUENCY PER FUNCTION | FIRST FUNCTION HERTZ 1ST BAND PASS 697.0 |
| REFERENCE FREQUENCY PER FUNCTION | FOURTH FUNCTION HERTZ 4TH BAND PASS 941.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FIFTH FUNCTION KILOHMS 5TH BAND PASS 1.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FOURTH FUNCTION KILOHMS 4TH BAND PASS 1.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | THIRD FUNCTION KILOHMS 3RD BAND PASS 1.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION KILOHMS 2ND BAND PASS 1.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION KILOHMS 1ST BAND PASS 1.0 |
| LOAD IMPEDANCE PER FUNCTION | FIFTH FUNCTION KILOHMS 5TH BAND PASS 100.0 |
| LOAD IMPEDANCE PER FUNCTION | FOURTH FUNCTION KILOHMS 4TH BAND PASS 100.0 |
| LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION KILOHMS 3RD BAND PASS 100.0 |
| LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION KILOHMS 2ND BAND PASS 100.0 |
| LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION KILOHMS 1ST BAND PASS 100.0 |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH BAND PASS |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED PIN(S) 14 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | FIRST FUNCTION 1ST BAND PASS 3.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | THIRD FUNCTION 3RD BAND PASS 3.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | FIFTH FUNCTION 5TH BAND PASS 3.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | FOURTH FUNCTION 4TH BAND PASS 3.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | SECOND FUNCTION 2ND BAND PASS 3.0 |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | THIRD FUNCTION PIN GROUND 1 |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION PIN OUTPUT 5 |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION PIN INPUT 1 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | FIRST FUNCTION HERTZ 1ST BAND PASS 676.00 AND HERTZ 1ST BAND PASS 684.00 AND HERTZ 1ST BAND PASS 710.00 AND HERTZ 1ST BAND PASS 718.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | FOURTH FUNCTION HERTZ 4TH BAND PASS 913.00 AND HERTZ 4TH BAND PASS 922.00 AND HERTZ 4TH BAND PASS 959.00 AND HERTZ 4TH BAND PASS 970.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | THIRD FUNCTION HERTZ 3RD BAND PASS 826.00 AND HERTZ 3RD BAND PASS 835.00 AND HERTZ 3RD BAND PASS 869.00 AND HERTZ 3RD BAND PASS 878.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | FIFTH FUNCTION HERTZ 5TH BAND PASS 551.00 AND HERTZ 5TH BAND PASS 558.00 AND HERTZ 5TH BAND PASS 582.00 AND HERTZ 5TH BAND PASS 589.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | SECOND FUNCTION HERTZ 2ND BAND PASS 747.00 AND HERTZ 2ND BAND PASS 755.00 AND HERTZ 2ND BAND PASS 785.00 AND HERTZ 2ND BAND PASS 794.00 |
| BODY MATERIAL | METAL |
| FREQUENCY BAND WIDTH PER FUNCTION | FOURTH FUNCTION HERTZ 4TH BAND PASS 922.00 AND HERTZ 4TH BAND PASS 959.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | SECOND FUNCTION HERTZ 2ND BAND PASS 755.00 AND HERTZ 2ND BAND PASS 785.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | FIRST FUNCTION HERTZ 1ST BAND PASS 684.00 AND HERTZ 1ST BAND PASS 710.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | THIRD FUNCTION HERTZ 3RD BAND PASS 835.00 AND HERTZ 3RD BAND PASS 869.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | FIFTH FUNCTION HERTZ 5TH BAND PASS 558.00 AND HERTZ 5TH BAND PASS 582.00 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIFTH FUNCTION MINIMUM 5TH BAND PASS 3.0 AND MAXIMUM 5TH BAND PASS 30.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | THIRD FUNCTION MINIMUM 3RD BAND PASS 3.0 AND MAXIMUM 3RD BAND PASS 30.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FOURTH FUNCTION MINIMUM 4TH BAND PASS 3.0 AND MAXIMUM 4TH BAND PASS 30.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM 1ST BAND PASS 3.0 AND MAXIMUM 1ST BAND PASS 30.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | SECOND FUNCTION MINIMUM 2ND BAND PASS 3.0 AND MAXIMUM 2ND BAND PASS 30.0 |
| BODY SURFACE TREATMENT | TIN |
| SPECIAL FEATURES | UNPACKAGED UNIT WEIGHT: OZ8.000 |
| STYLE DESIGNATOR |
MOE rules
- MOE rule
- A918
- MOE CD
- DA
- AMC
- 1
- AMSC
- C
- Date assigned
- 01-JUN-06
- IMC
- Z
- IMCA
- CD
- PICA
- GX
- PICA LOA
- 01
- SICA
- CD
- SICA LOA
- 5D
- Auth collab
- CD GX
- Fmr MOE rl
- A196
Service data
Army
- Matcat 1
- Q
- Matcat 2
- 2
- Matcat 3
- 2
- Matcat 4 5
- RH
- ARC
- X
Freight
- ACTY CD
- TX
- NMFC
- 061990
- NMFC sub
- X
- Uniform freight class
- 58500
- Less than truckload
- P
- Water commodity code
- 593
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELECTRICAL EQUIP:FILTERS
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- EAMIL-DTL-17667, neutral wrapping paper
- Cush dun
- BGA-A-1898, Grade II, water resistant cellulosic cushioning
- THK
- C3/4 inch thick
- Unit cont
- D1PPP-B-566 or PPP-B-676, folding or setup box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.5000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0040
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 29-JAN-1976
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.