Catalog item

FILTER,BAND PASS

5915FSC
01NCB code
023-8930Item number
NIIN 01-023-8930
Request a quote
Unit price
$786.43
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
29-JUN-76
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$786.431U0ZQ2200X-$0.00A
01-OCT-2026DSJSMSEA0.0000$786.431U0N-------$0.00I

Part numbers

Part number
43030020-002
CAGE
96238
DNE TECHNOLOGIES, INC
CAGE status
A
RNCC
3
RNVC
2
Document availability code
5
RNAAC
TX
RNFC
1
RNSC
D

Characteristics

OVERALL HEIGHTINCHES NOMINAL 0.928
BODY LENGTHINCHES NOMINAL 1.885
BODY WIDTHINCHES NOMINAL 1.445
BODY HEIGHTINCHES NOMINAL 0.796
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.250
OPERATING TEMP RANGECELSIUS -55.0 TO 85.0
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 850.0
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 850.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 850.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 50.0
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED TERMINAL 5
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND PASS 3.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 3
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 2
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 750.00 AND HERTZ 1ST BAND PASS 800.00 AND HERTZ 1ST BAND PASS 900.00 AND HERTZ 1ST BAND PASS 950.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 750.00 AND HERTZ 3RD BAND PASS 800.00 AND HERTZ 3RD BAND PASS 900.00 AND HERTZ 3RD BAND PASS 950.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 750.00 AND HERTZ 2ND BAND PASS 800.00 AND HERTZ 2ND BAND PASS 900.00 AND HERTZ 2ND BAND PASS 950.00
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION HERTZ 3RD BAND PASS 800.00 AND HERTZ 3RD BAND PASS 900.00
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION HERTZ 1ST BAND PASS 800.00 AND HERTZ 1ST BAND PASS 900.00
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION HERTZ 2ND BAND PASS 800.00 AND HERTZ 2ND BAND PASS 900.00
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 3.0 AND MAXIMUM 1ST BAND PASS 60.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND PASS 3.0 AND MAXIMUM 3RD BAND PASS 60.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 3.0 AND MAXIMUM 2ND BAND PASS 60.0
SPECIAL FEATURESTHREE FILTERED FUNCTIONS
STYLE DESIGNATOR

MOE rules

MOE rule
A918
MOE CD
DA
AMC
5
AMSC
L
Date assigned
01-JUN-06
IMC
Z
IMCA
CD
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
29-JUN-1976
NIIN status code
0

Request a quote