Catalog item

FILTER,BAND PASS

5915FSC
01NCB code
029-2039Item number
NIIN 01-029-2039
Request a quote
Unit price
$1,449.75
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
16-OCT-76
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$1,449.751U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,449.751U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
441133791
ELECTRONIC PRECISION COMPONENTS CORP B G ELECTRONICS DIV
H595HD4B
4429033791
ELECTRONIC PRECISION COMPONENTS CORP B G ELECTRONICS DIV
H395HD1A
44290-198853
HAMILTON STANDARD ELECTRONICS SYSTEMS INC TELE-DYNAMICS DIV
H591HD1B

Characteristics

OVERALL HEIGHTINCHES NOMINAL 0.993
BODY LENGTHINCHES NOMINAL 6.000
BODY WIDTHINCHES NOMINAL 1.750
BODY HEIGHTINCHES NOMINAL 0.868
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 5.000
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.250
REFERENCE FREQUENCY PER FUNCTIONFOURTH FUNCTION KILOHERTZ 4TH BAND PASS 33.2
REFERENCE FREQUENCY PER FUNCTIONFIFTH FUNCTION KILOHERTZ 5TH BAND PASS 35.6
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 28.4
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND PASS 30.8
REFERENCE FREQUENCY PER FUNCTIONSIXTH FUNCTION KILOHERTZ 6TH BAND PASS 38.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 26.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION OHMS 5TH BAND PASS 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION OHMS 6TH BAND PASS 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH BAND PASS 1.0
LOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION OHMS 6TH BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION OHMS 5TH BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 50.0
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 12
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSIXTH FUNCTION 6TH BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIFTH FUNCTION 5TH BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFOURTH FUNCTION 4TH BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 3.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN INPUT-OUTPUT/GROUND 6
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 1
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 1
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIFTH FUNCTION KILOHERTZ 5TH BAND PASS 33.20 AND KILOHERTZ 5TH BAND PASS 35.50 AND KILOHERTZ 5TH BAND PASS 35.70 AND KILOHERTZ 5TH BAND PASS 38.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND PASS 28.40 AND KILOHERTZ 3RD BAND PASS 30.70 AND KILOHERTZ 3RD BAND PASS 30.90 AND KILOHERTZ 3RD BAND PASS 33.20
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 22.80 AND KILOHERTZ 1ST BAND PASS 25.90 AND KILOHERTZ 1ST BAND PASS 26.10 AND KILOHERTZ 1ST BAND PASS 28.40
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 26.40 AND KILOHERTZ 2ND BAND PASS 28.30 AND KILOHERTZ 2ND BAND PASS 28.50 AND KILOHERTZ 2ND BAND PASS 30.80
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFOURTH FUNCTION KILOHERTZ 4TH BAND PASS 30.80 AND KILOHERTZ 4TH BAND PASS 33.10 AND KILOHERTZ 4TH BAND PASS 33.30 AND KILOHERTZ 4TH BAND PASS 35.60
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSIXTH FUNCTION KILOHERTZ 6TH BAND PASS 35.60 AND KILOHERTZ 6TH BAND PASS 37.90 AND KILOHERTZ 6TH BAND PASS 38.10 AND KILOHERTZ 6TH BAND PASS 43.00
NOMINAL THREAD SIZEINCHES 0.112
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 25.90 AND KILOHERTZ 1ST BAND PASS 26.10
FREQUENCY BAND WIDTH PER FUNCTIONFOURTH FUNCTION KILOHERTZ 4TH BAND PASS 33.10 AND KILOHERTZ 4TH BAND PASS 33.30
FREQUENCY BAND WIDTH PER FUNCTIONSIXTH FUNCTION KILOHERTZ 6TH BAND PASS 37.90 AND KILOHERTZ 6TH BAND PASS 38.10
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 28.30 AND KILOHERTZ 2ND BAND PASS 28.50
FREQUENCY BAND WIDTH PER FUNCTIONFIFTH FUNCTION KILOHERTZ 5TH BAND PASS 35.50 AND KILOHERTZ 5TH BAND PASS 35.70
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND PASS 30.70 AND KILOHERTZ 3RD BAND PASS 30.90
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 30.0 AND MAXIMUM 2ND BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSIXTH FUNCTION MINIMUM 6TH BAND PASS 30.0 AND MAXIMUM 6TH BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIFTH FUNCTION MINIMUM 5TH BAND PASS 30.0 AND MAXIMUM 5TH BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFOURTH FUNCTION MINIMUM 4TH BAND PASS 30.0 AND MAXIMUM 4TH BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND PASS 30.0 AND MAXIMUM 3RD BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 30.0 AND MAXIMUM 1ST BAND PASS 3.0
BODY SURFACE TREATMENTTIN
STYLE DESIGNATOR

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZW01ZW01-NOV-98ZW81ZW
N9BNDN1G01-JUN-06ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
HD
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
16-OCT-1976
NIIN status code
0

Request a quote