Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
01NCB code
032-5421Item number
NIIN 01-032-5421
Request a quote
Unit price
$1,053.74
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00765
PINC
0000765
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
15-DEC-76
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$1,053.741709B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,053.74170-------$0.00I

Part numbers

Part number
158626-01
CAGE
35351
GE AVIATION SYSTEMS LLC
CAGE status
A
RNCC
3
RNVC
2
Document availability code
1
RNAAC
TX
RNFC
1
RNSC
D

Characteristics

OVERALL HEIGHTINCHES MAXIMUM 3.544
BODY LENGTHINCHES MAXIMUM 3.030
BODY WIDTHINCHES MAXIMUM 1.360
BODY HEIGHTINCHES MAXIMUM 2.750
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.000
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.825
OPERATING TEMP RANGECELSIUS -54.0 TO 110.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSIXTH FUNCTION 6TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIFTH FUNCTION 5TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFOURTH FUNCTION 4TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 400.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 1.5
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 1.5
OPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 1.5
OPERATING CURRENT RATING PER FUNCTION IN AMPSSIXTH FUNCTION 3RD RADIO INTERFERENCE 3.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIFTH FUNCTION 5TH RADIO INTERFERENCE 3.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 3.0
MAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 1.0
MAXIMUM VOLTAGE DROP PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 1.0
MAXIMUM VOLTAGE DROP PER FUNCTIONFIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 1.0
MAXIMUM VOLTAGE DROP PER FUNCTIONFOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 1.0
MAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.0
MAXIMUM VOLTAGE DROP PER FUNCTIONSIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 1.0
INPUT TERMINAL MANUFACTURER CODE96906
INPUT TERMINAL IDENTIFICATIONMS27478Y12D98P
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 4
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION TAB, SOLDER LUG OUTPUT 8
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION TAB, SOLDER LUG GROUND 1
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 115.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 115.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 115.0
NOMINAL THREAD SIZEINCHES 0.112
BODY MATERIALMETAL
UNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 1.000
SPECIAL FEATURESSEVEN FUNCTIONS
STYLE DESIGNATOR

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZU01ZU01-JUL-05ZU81ZU
N9BNDN5L01-JUN-06ZKEGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
BG
A-A-1898, Grade II, water resistant cellulosic cushioning
THK
C
3/4 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0250
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
23-AUG-1989
NIIN status code
0

Request a quote