Catalog item

FILTER,BAND PASS

5915FSC
01NCB code
107-0595Item number
NIIN 01-107-0595
Request a quote
Unit price
$1,158.69
Unit of issue
EA
Source of supply
SMS
DEMIL code
B

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
B
DEMIL integrity code
3
NIIN assigned
30-JAN-81
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$1,158.691U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,158.691U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
CC0107-1232840
CONOLOG CORPORATION DBA INIVEN
A525TX
262413-1294580
HONEYWELL INTERNATIONAL INC. DBA HONEYWELL INTERNATIONAL DIV AEROSPACE-MINNEAPOLIS
AC16ZZAC
262413-1201534
RAYTHEON COMPANY DBA RAYTHEON CO
A325TX4D

Characteristics

OVERALL HEIGHTINCHES NOMINAL 3.230
BODY LENGTHINCHES NOMINAL 3.000
BODY WIDTHINCHES MAXIMUM 1.410
BODY HEIGHTINCHES NOMINAL 2.950
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
OPERATING TEMP RANGECELSIUS -55.0 TO 65.0
AVERAGE LIFE RATING IN HOURS10000.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 2.295
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 2.295
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND PASS 2.295
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 600.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 600.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 600.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 600.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 600.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 600.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITYFIRST FUNCTION THREADED STUD(S) 2
MOUNTING FACILITY TYPE AND QUANTITYSECOND FUNCTION THREADED HOLE(S) 4
FEATURES PROVIDEDELECTROSTATIC SHIELD
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND PASS 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 3.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION TURRET OUTPUT 3
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION TURRET INPUT 2
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION TURRET GROUND 1
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 2.2525 AND KILOHERTZ 2ND BAND PASS 2.27375 AND KILOHERTZ 2ND BAND PASS 2.31625 AND KILOHERTZ 2ND BAND PASS 2.3375
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND PASS 2.2525 AND KILOHERTZ 3RD BAND PASS 2.27375 AND KILOHERTZ 3RD BAND PASS 2.31625 AND KILOHERTZ 3RD BAND PASS 2.3375
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 2.2525 AND KILOHERTZ 1ST BAND PASS 2.27375 AND KILOHERTZ 1ST BAND PASS 2.31625 AND KILOHERTZ 1ST BAND PASS 2.3375
NOMINAL THREAD SIZEINCHES 0.138
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 2.27375 AND KILOHERTZ 1ST BAND PASS 2.31625
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND PASS 2.27375 AND KILOHERTZ 3RD BAND PASS 2.31625
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 2.27375 AND KILOHERTZ 2ND BAND PASS 2.31625
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 3.0 AND MAXIMUM 1ST BAND PASS 30.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND PASS 3.0 AND MAXIMUM 3RD BAND PASS 30.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 3.0 AND MAXIMUM 2ND BAND PASS 30.0
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEVOLTS AT SEA LEVEL 500.0
SPECIAL FEATURESELECTROSTATIC SHIELD BROUGHT OUT TO TERMINAL SIX
STYLE DESIGNATOR

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
1
AMSC
G
Date assigned
01-JUN-06
IMC
Z
IMCA
HD
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
HD
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
1.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0690
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
30-JAN-1981
NIIN status code
0

Request a quote