Catalog item
Request a quoteFILTER,RADIO FREQUENCY INTERFERE
5915FSC
01NCB code
142-1545Item number
NIIN 01-142-1545
- Unit price
- $951.15
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00765
- PINC
- 0000765
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 12-NOV-82
- Precious metals indicator
- C
- Hazardous material indicator
- P
- Schedule B export code
- 8527995030
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DA | J | SMS | EA | 0.0000 | $951.15 | 1 | U | 0 | A | Q2200X- | $0.00 | A |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $951.15 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
Characteristics
| OVERALL LENGTH | INCHES MAXIMUM 1.590 |
|---|---|
| OVERALL HEIGHT | INCHES MAXIMUM 1.828 |
| OVERALL WIDTH | INCHES MAXIMUM 1.828 |
| VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
| OPERATING TEMP RANGE | CELSIUS -55.0 TO 125.0 |
| END ITEM IDENTIFICATION | COUNTERMEASURES SET,SPECIAL PURPOSE AN/MLQ-34 |
| SOURCE IMPEDANCE RATING PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| LOAD IMPEDANCE PER FUNCTION | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| LOAD IMPEDANCE PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| LOAD IMPEDANCE PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 400.0 |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FOURTH FUNCTION 4TH RADIO INTERFERENCE 400.0 |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIFTH FUNCTION 5TH RADIO INTERFERENCE 400.0 |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 400.0 |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | THIRD FUNCTION 3RD RADIO INTERFERENCE 400.0 |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SIXTH FUNCTION 6TH RADIO INTERFERENCE 400.0 |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | THIRD FUNCTION 3RD RADIO INTERFERENCE 7.5 |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 7.5 |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 7.5 |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | FOURTH FUNCTION 4TH RADIO INTERFERENCE 7.5 |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIFTH FUNCTION 5TH RADIO INTERFERENCE 7.5 |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | SIXTH FUNCTION 6TH RADIO INTERFERENCE 7.5 |
| MAXIMUM VOLTAGE DROP PER FUNCTION | FIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 1.2 AND VOLTS DC 5TH RADIO INTERFERENCE 2.0 |
| MAXIMUM VOLTAGE DROP PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 1.2 AND VOLTS DC 4TH RADIO INTERFERENCE 2.0 |
| MAXIMUM VOLTAGE DROP PER FUNCTION | SIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 1.2 AND VOLTS DC 6TH RADIO INTERFERENCE 2.0 |
| MAXIMUM VOLTAGE DROP PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.2 AND VOLTS DC 1ST RADIO INTERFERENCE 2.0 |
| MAXIMUM VOLTAGE DROP PER FUNCTION | THIRD FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.2 AND VOLTS DC 3RD RADIO INTERFERENCE 2.0 |
| MAXIMUM VOLTAGE DROP PER FUNCTION | SECOND FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.2 AND VOLTS DC 2ND RADIO INTERFERENCE 2.0 |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| INPUT TERMINAL MANUFACTURER CODE | 57958 |
| INPUT TERMINAL IDENTIFICATION | MIL-C-26074 |
| OUTPUT TERMINAL MANUFACTURER CODE | 57958 |
| OUTPUT TERMINAL IDENTIFICATION | MIL-C-26074 |
| MAXIMUM TEMP RISE | CELSIUS 25.0 |
| FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 1.0 AND 2.0 AND 10.0 AND 100.0 AND 500.0 AND 1000.0 |
| FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 2.0 AND 5.0 AND 18.0 AND 50.0 AND 60.0 |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED BUSHING 1 |
| FEATURES PROVIDED | NUT |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT 41 |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 120.0 AND VOLTS DC 4TH RADIO INTERFERENCE 200.0 |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 120.0 AND VOLTS DC 5TH RADIO INTERFERENCE 200.0 |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 120.0 AND VOLTS DC 2ND RADIO INTERFERENCE 200.0 |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 120.0 AND VOLTS DC 3RD RADIO INTERFERENCE 200.0 |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 120.0 AND VOLTS DC 6TH RADIO INTERFERENCE 200.0 |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 120.0 AND VOLTS DC 1ST RADIO INTERFERENCE 200.0 |
| NOMINAL THREAD SIZE | INCHES 0.812 |
| BODY MATERIAL | ALUMINUM |
| MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | KILOVOLTS AT SEA LEVEL 1.2 |
| BODY SURFACE TREATMENT | NICKEL |
| SPECIAL FEATURES | FORTY-ONE FILTERED FUNCTIONS |
| PRECIOUS MATERIAL AND LOCATION | GOLD CONTACT SURFACES AND SILVER GROUND LANE SURFACES |
| PRECIOUS MATERIAL | GOLD AND SILVER |
| STYLE DESIGNATOR |
MOE rules
- MOE rule
- A918
- MOE CD
- DA
- AMC
- 3
- AMSC
- Z
- Date assigned
- 01-JUN-06
- IMC
- Z
- IMCA
- CD
- PICA
- GX
- PICA LOA
- 01
- SICA
- CD
- SICA LOA
- 5D
- Auth collab
- CD GX
- Fmr MOE rl
- A196
Service data
Army
- Matcat 1
- Q
- Matcat 2
- 2
- Matcat 3
- 2
- Matcat 4 5
- 00
- ARC
- X
Freight
- ACTY CD
- TX
- NMFC
- 061990
- NMFC sub
- X
- Uniform freight class
- 58500
- Less than truckload
- P
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELECTRICAL EQUIP:FILTERS
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- XXX
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- PRESERVATION AND PACKAGING
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 12-NOV-1982
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.