Catalog item

FILTER,BAND PASS

5915FSC
01NCB code
149-9396Item number
NIIN 01-149-9396
Request a quote
Unit price
$1,239.26
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
28-MAR-83
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAXSMSEA0.0000$1,239.261U0ZQ2200X-$0.00A
01-OCT-2026DSXSMSEA0.0000$1,239.261U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
TSF160.5-1.6-6XX104423
TELONIC BERKELEY, INC. DBA TELONIC BERKELEY
A525TX
64-9402-0104423
TELONIC BERKELEY, INC. DBA TELONIC BERKELEY
A32ATX

Characteristics

OVERALL LENGTHINCHES NOMINAL 7.750
OVERALL HEIGHTINCHES NOMINAL 1.312
BODY LENGTHINCHES NOMINAL 7.000
BODY WIDTHINCHES NOMINAL 1.875
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 7.375
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.120
OPERATING TEMP RANGECELSIUS -0.0 TO 50.0
REFERENCE FREQUENCY PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 160.5
INPUT IMPEDANCE PER FUNCTION W/LOADLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0
INPUT TERMINAL MANUFACTURER CODE98291
INPUT TERMINAL IDENTIFICATION50-048-0000
OUTPUT TERMINAL MANUFACTURER CODE98291
OUTPUT TERMINAL IDENTIFICATION50-048-0000
VOLTAGE STANDING WAVE RATIO PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED BLANK 1.5
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED SLOT 4
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSLOCATION NOT OTHERWISE SPECIFIED BLANK 8.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION CONNECTOR, RECEPTACLE OUTPUT 1
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 157.90 AND MEGAHERTZ BLANK 159.70 AND MEGAHERTZ BLANK 161.30 AND MEGAHERTZ BLANK 163.70
FREQUENCY BAND WIDTH PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 159.70 AND MEGAHERTZ BLANK 161.30
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM BLANK 60.0 AND MAXIMUM BLANK 3.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 159.9 AND MEGAHERTZ BLANK 161.1
STYLE DESIGNATOR

MOE rules

MOE rule
A918
MOE CD
DA
AMC
3
AMSC
L
Date assigned
01-JUN-06
IMC
Z
IMCA
CD
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0280
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
28-MAR-1983
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.