Catalog item

FILTER,BAND SUPPRESSION

5915FSC
01NCB code
150-6416Item number
NIIN 01-150-6416
Request a quote
Unit price
$1,382.57
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00210
PINC
0000210
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
07-APR-83
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAXSMSEA0.0000$1,382.571U0ZQ2200X-$0.00A
01-OCT-2026DSXSMSEA0.0000$1,382.571U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
SM-A-838214-154832
AEROFLEX LABORATORIES INC COMSTRON DIV
A525TX
SM-A-838214-157996
FILTER RESEARCH CORPORATION DBA FILTER RESEARCH CORP
A595TXB
SM-A-838214-180063
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
A32ATX
R-162108715
CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC
A595TXB

Characteristics

OVERALL HEIGHTINCHES MAXIMUM 0.850
BODY LENGTHINCHES MAXIMUM 3.035
BODY WIDTHINCHES MAXIMUM 2.250
BODY HEIGHTINCHES MAXIMUM 0.580
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.500
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.750
OPERATING TEMP RANGECELSIUS -29.0 TO 85.0
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND SUPPRESSION 13.16
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND SUPPRESSION 30.76
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION KILOHMS 1ST BAND SUPPRESSION 1.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION KILOHMS 2ND BAND SUPPRESSION 1.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION KILOHMS 1ST BAND SUPPRESSION 1.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION KILOHMS 2ND BAND SUPPRESSION 1.0
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND SUPPRESSION 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND SUPPRESSION 3.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 2
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN GROUND 1
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 2
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND SUPPRESSION 8.00 AND KILOHERTZ 2ND BAND SUPPRESSION 10.88 AND KILOHERTZ 2ND BAND SUPPRESSION 15.44 AND KILOHERTZ 2ND BAND SUPPRESSION 18.88
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND SUPPRESSION 15.44 AND KILOHERTZ 1ST BAND SUPPRESSION 18.88 AND KILOHERTZ 1ST BAND SUPPRESSION 42.64 AND KILOHERTZ 1ST BAND SUPPRESSION 52.00
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND SUPPRESSION 10.88 AND KILOHERTZ 2ND BAND SUPPRESSION 15.44
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND SUPPRESSION 18.88 AND KILOHERTZ 1ST BAND SUPPRESSION 42.64
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MAXIMUM 2ND BAND SUPPRESSION 7.5 AND MINIMUM 2ND BAND SUPPRESSION 25.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MAXIMUM 1ST BAND SUPPRESSION 7.5 AND MINIMUM 1ST BAND SUPPRESSION 25.0
STYLE DESIGNATOR

MOE rules

MOE rule
A918
MOE CD
DA
AMC
3
AMSC
C
Date assigned
01-JUN-06
IMC
Z
IMCA
CD
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Supp collab
CL
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
93279

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
07-APR-1983
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.