Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
01NCB code
228-6739Item number
NIIN 01-228-6739
Request a quote
Unit price
$7,309.50
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00765
PINC
0000765
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
20-MAR-86
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$7,309.501709B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$7,309.50170-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
1503804G128528
ITT INDUSTRIES INC ITT AEROSPACE COMMUNICATIONS DIV EAST
R39BTX
52-755-00133095
SPECTRUM CONTROL INC
A595TX
1503804G131550
L3HARRIS TECHNOLOGIES, INC. DBA HARRIS CORPORATION
A525ZZ

Characteristics

OVERALL HEIGHTINCHES NOMINAL 1.000
BODY LENGTHINCHES NOMINAL 3.670
BODY WIDTHINCHES MAXIMUM 0.500
BODY HEIGHTINCHES NOMINAL 0.375
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 0.400
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 2000.0
OPERATING TEMP RANGECELSIUS -55.0 TO 125.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 1.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 1.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 1.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIFTH FUNCTION 5TH RADIO INTERFERENCE 1.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSIXTH FUNCTION 6TH RADIO INTERFERENCE 1.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 1.0
MAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION VOLTS DC 2ND RADIO INTERFERENCE 0.1
MAXIMUM VOLTAGE DROP PER FUNCTIONTHIRD FUNCTION VOLTS DC 3RD RADIO INTERFERENCE 0.1
MAXIMUM VOLTAGE DROP PER FUNCTIONFIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 0.1
MAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION VOLTS DC 1ST RADIO INTERFERENCE 0.1
MAXIMUM VOLTAGE DROP PER FUNCTIONFOURTH FUNCTION VOLTS DC 4TH RADIO INTERFERENCE 0.1
MAXIMUM VOLTAGE DROP PER FUNCTIONSIXTH FUNCTION VOLTS DC 6TH RADIO INTERFERENCE 0.1
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
MAXIMUM TEMP RISECELSIUS 15.0
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ3.0 AND 10.0 AND 30.0 AND 100.0 AND 300.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS7.0 AND 12.0 AND 35.0 AND 60.0 AND 70.0 AND 70.0
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 8
FEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 18
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 18
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS DC 2ND RADIO INTERFERENCE 100.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS DC 1ST RADIO INTERFERENCE 100.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSIXTH FUNCTION VOLTS DC 6TH RADIO INTERFERENCE 100.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 100.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS DC 3RD RADIO INTERFERENCE 100.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS DC 4TH RADIO INTERFERENCE 100.0
NOMINAL THREAD SIZEINCHES 0.086
BODY MATERIALALUMINUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEVOLTS AT SEA LEVEL 200.0
BODY SURFACE TREATMENTTIN
SPECIAL FEATURESEIGHTEEN FILTERED FUNCTIONS
PROPRIETARY CHARACTERISTICSPACS
STYLE DESIGNATOR

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JUL-04WP81WP
YB01YB01-JUN-03YB81YB
ZW01ZW01-NOV-98ZW81ZW
N9BNDN5C01-JUN-06ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
22-MAR-1986
NIIN status code
0

Request a quote