Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
01NCB code
246-9642Item number
NIIN 01-246-9642
Request a quote
Unit price
$2,353.65
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00765
PINC
0000765
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
22-DEC-86
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAXSMSEA0.0000$2,353.651U0ZQ2200X-$0.00A
01-OCT-2026DSXSMSEA0.0000$2,353.651U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
A-457123939
THE CAPTOR CORPORATION
A526TX
L51700009336090
LOCKHEED MARTIN LIBRASCOPE CORPORATION
A525TX
B401223856996
DEPARTMENT OF THE ARMY HQ UNITED STATES ARMY COMMUNICATIONS RESEARCH AND DEVELOPMENT COMMAND
A32ATX
NF2115605245
TE CONNECTIVITY CORPORATION DIV CORCOM
A526TX

Characteristics

BODY LENGTHINCHES NOMINAL 5.680
BODY WIDTHINCHES NOMINAL 4.810
BODY HEIGHTINCHES NOMINAL 2.120
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 5.125
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 2000.0
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 4.250
OPERATING TEMP RANGECELSIUS -45.0 TO 85.0
END ITEM IDENTIFICATION7010-01-085-4310 COMPUTER TERMIN
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 100.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 100.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 25.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIFTH FUNCTION 5TH RADIO INTERFERENCE 25.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSIXTH FUNCTION 6TH RADIO INTERFERENCE 25.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 25.0
MAXIMUM VOLTAGE DROP PER FUNCTIONFIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 0.28
MAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION VOLTS DC 1ST RADIO INTERFERENCE 0.28
MAXIMUM VOLTAGE DROP PER FUNCTIONFOURTH FUNCTION VOLTS DC 4TH RADIO INTERFERENCE 0.28
MAXIMUM VOLTAGE DROP PER FUNCTIONSIXTH FUNCTION VOLTS DC 6TH RADIO INTERFERENCE 0.28
MAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION VOLTS DC 2ND RADIO INTERFERENCE 0.28
MAXIMUM VOLTAGE DROP PER FUNCTIONTHIRD FUNCTION VOLTS DC 3RD RADIO INTERFERENCE 0.28
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
INPUT TERMINAL MANUFACTURER CODE96906
INPUT TERMINAL IDENTIFICATIONMS17346C32C1P
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 8
FEATURES PROVIDEDSHOCK RESISTANT
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 3
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION THREADED STUD OUTPUT 6
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSIXTH FUNCTION VOLTS DC 6TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS DC 4TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS DC 3RD RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS DC 1ST RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS DC 2ND RADIO INTERFERENCE 28.0
NOMINAL THREAD SIZEINCHES 0.164
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
STYLE DESIGNATOR

MOE rules

MOE rule
A918
MOE CD
DA
AMC
1
AMSC
C
Date assigned
01-JUL-05
IMC
Z
IMCA
CD
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Supp collab
CL
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
TH
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
93032

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
23-AUG-1989
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.