Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
01NCB code
254-0719Item number
NIIN 01-254-0719
Request a quote
Unit price
$142.21
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
00765
PINC
0000765
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
30-APR-87
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$142.211U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$142.211U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
20JX5306A56289
SPRAGUE ELECTRIC CO WORLD HQS
A32ETX
7140032-110236
ELECTRODYNAMICS INC DIV L3HARRIS ELECTRODYNAMICS INC
A525TX

Characteristics

OVERALL LENGTHINCHES MAXIMUM 4.140
OVERALL HEIGHTINCHES MINIMUM 1.470 AND INCHES MAXIMUM 1.530
OVERALL WIDTHINCHES NOMINAL 5.435
BODY LENGTHINCHES MINIMUM 3.282 AND INCHES MAXIMUM 3.342
BODY WIDTHINCHES MINIMUM 3.845 AND INCHES MAXIMUM 3.905
UNTHREADED MOUNTING HOLE DIAMETERINCHES MINIMUM 0.142 AND INCHES MAXIMUM 0.146
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 3.735 AND INCHES MAXIMUM 3.765
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 2.000
OPERATING TEMP RANGECELSIUS -55.0 TO 85.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 400.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 20.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 20.0
MAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.25
MAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 1.25
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
MAXIMUM TEMP RISECELSIUS 25.0
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS20.0 AND 30.0 AND 55.0 AND 65.0 AND 70.0
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4
FEATURES PROVIDEDNUT AND WASHER
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION THREADED STUD OUTPUT 2
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION THREADED STUD GROUND 1
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION THREADED STUD INPUT 2
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 125.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 125.0
BODY MATERIALMETAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEKILOVOLTS AT SEA LEVEL 1.45
SPECIAL FEATURESTWO FILTERED FUNCTIONS
STYLE DESIGNATOR

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
ZC01ZC01-APR-91ZC81ZC
FXGXDF5H01-JUN-06ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
23-AUG-1989
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.