Catalog item
Request a quoteFILTER,BAND PASS
5915FSC
01NCB code
262-1719Item number
NIIN 01-262-1719
- Unit price
- $4,784.15
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- D
Identification
- Item name code
- 00209
- PINC
- 0000209
- Criticality code
- X
- II
- 0
- DEMIL code
- D
- DEMIL integrity code
- 1
- NIIN assigned
- 24-AUG-87
- Precious metals indicator
- S
- Hazardous material indicator
- P
- Schedule B export code
- 8527995030
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DF | J | SMS | EA | 0.0000 | $4,784.15 | 1 | 7 | 0 | N | SF9EH-N | $0.00 | F |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $4,784.15 | 1 | 7 | 0 | N | ------- | $0.00 | I |
Part numbers
Characteristics
| OVERALL LENGTH | INCHES NOMINAL 1.720 |
|---|---|
| OVERALL HEIGHT | INCHES NOMINAL 0.380 |
| OVERALL WIDTH | INCHES NOMINAL 3.780 |
| BODY LENGTH | INCHES NOMINAL 1.320 |
| BODY WIDTH | INCHES NOMINAL 3.500 |
| UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.120 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 1.520 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 2.000 |
| OPERATING TEMP RANGE | CELSIUS -46.0 TO 75.0 |
| AVERAGE LIFE RATING IN HOURS | 10000.0 |
| REFERENCE FREQUENCY PER FUNCTION | FOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 640.0 |
| REFERENCE FREQUENCY PER FUNCTION | SECOND FUNCTION MEGAHERTZ 2ND BAND PASS 660.0 |
| REFERENCE FREQUENCY PER FUNCTION | THIRD FUNCTION MEGAHERTZ 3RD BAND PASS 680.0 |
| REFERENCE FREQUENCY PER FUNCTION | FIRST FUNCTION MEGAHERTZ 1ST BAND PASS 620.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FOURTH FUNCTION OHMS 4TH BAND PASS 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | THIRD FUNCTION OHMS 3RD BAND PASS 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST BAND PASS 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND BAND PASS 50.0 |
| LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION OHMS 3RD BAND PASS 50.0 |
| LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST BAND PASS 50.0 |
| LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND BAND PASS 50.0 |
| LOAD IMPEDANCE PER FUNCTION | FOURTH FUNCTION OHMS 4TH BAND PASS 50.0 |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD BAND PASS |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | FOURTH FUNCTION 4TH BAND PASS 1.5 |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | THIRD FUNCTION 3RD BAND PASS 1.5 |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | SECOND FUNCTION 2ND BAND PASS 1.5 |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | FIRST FUNCTION 1ST BAND PASS 1.5 |
| INCLOSURE TYPE | ENCASED |
| MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | FOURTH FUNCTION 4TH BAND PASS 5.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | THIRD FUNCTION 3RD BAND PASS 5.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | FIRST FUNCTION 1ST BAND PASS 5.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | SECOND FUNCTION 2ND BAND PASS 5.0 |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION PIN INPUT 4 |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION PIN OUTPUT 4 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | FOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 620.00 AND MEGAHERTZ 4TH BAND PASS 639.00 AND MEGAHERTZ 4TH BAND PASS 641.00 AND MEGAHERTZ 4TH BAND PASS 660.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | SECOND FUNCTION MEGAHERTZ 2ND BAND PASS 640.00 AND MEGAHERTZ 2ND BAND PASS 659.00 AND MEGAHERTZ 2ND BAND PASS 661.00 AND MEGAHERTZ 2ND BAND PASS 680.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | FIRST FUNCTION MEGAHERTZ 1ST BAND PASS 600.00 AND MEGAHERTZ 1ST BAND PASS 619.00 AND MEGAHERTZ 1ST BAND PASS 621.00 AND MEGAHERTZ 1ST BAND PASS 640.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | THIRD FUNCTION MEGAHERTZ 3RD BAND PASS 660.00 AND MEGAHERTZ 3RD BAND PASS 679.00 AND MEGAHERTZ 3RD BAND PASS 681.00 AND MEGAHERTZ 3RD BAND PASS 700.00 |
| BODY MATERIAL | ALUMINUM |
| FREQUENCY BAND WIDTH PER FUNCTION | THIRD FUNCTION MEGAHERTZ 3RD BAND PASS 679.00 AND MEGAHERTZ 3RD BAND PASS 681.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | FOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 639.00 AND MEGAHERTZ 4TH BAND PASS 641.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | SECOND FUNCTION MEGAHERTZ 2ND BAND PASS 659.00 AND MEGAHERTZ 2ND BAND PASS 661.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | FIRST FUNCTION MEGAHERTZ 1ST BAND PASS 619.00 AND MEGAHERTZ 1ST BAND PASS 621.00 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM 1ST BAND PASS 40.0 AND MAXIMUM 1ST BAND PASS 5.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | THIRD FUNCTION MINIMUM 3RD BAND PASS 40.0 AND MAXIMUM 3RD BAND PASS 5.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FOURTH FUNCTION MINIMUM 4TH BAND PASS 40.0 AND MAXIMUM 4TH BAND PASS 5.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | SECOND FUNCTION MINIMUM 2ND BAND PASS 40.0 AND MAXIMUM 2ND BAND PASS 5.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | THIRD FUNCTION MEGAHERTZ 3RD BAND PASS 679.0 AND MEGAHERTZ 3RD BAND PASS 681.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | FOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 639.0 AND MEGAHERTZ 4TH BAND PASS 641.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | FIRST FUNCTION MEGAHERTZ 1ST BAND PASS 619.0 AND MEGAHERTZ 1ST BAND PASS 621.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | SECOND FUNCTION MEGAHERTZ 2ND BAND PASS 659.0 AND MEGAHERTZ 2ND BAND PASS 661.0 |
| PRECIOUS MATERIAL AND LOCATION | SILVER TER-INAL SURFACES |
| PRECIOUS MATERIAL | SILVER |
| STYLE DESIGNATOR |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WP01 | WP | 01-JUN-07 | WP | 81 | WP | |||||||
| YD01 | YD | 01-NOV-16 | YD | 81 | YD | |||||||
| ZU01 | ZU | 01-MAY-08 | ZU | 81 | ZU | |||||||
| FXGX | DF | 1 | C | 01-JUL-05 | Z | SX | GX | 01 | SX | 5D | GX TU | FXTX |
Service data
Air Force
- Fund
- SF
- Budget
- 9
- MMAC
- EH
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- TH
- NMFC
- 061990
- NMFC sub
- X
- Uniform freight class
- 58500
- Less than truckload
- P
- Water commodity code
- 593
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELECTRICAL EQUIP:FILTERS
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- NAPPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.2000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0690
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 24-AUG-1987
- NIIN status code
- 0
Request a quote