Catalog item

FILTER,BAND PASS

5915FSC
01NCB code
262-1719Item number
NIIN 01-262-1719
Request a quote
Unit price
$4,784.15
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
24-AUG-87
Precious metals indicator
S
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$4,784.15170NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$4,784.15170N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
3323750140
K&L MICROWAVE LLC DIV MPG HOLDING COMPANY
A525TX
586R665H0250140
K&L MICROWAVE LLC DIV MPG HOLDING COMPANY
A595TXB
586R665H0297942
NORTHROP GRUMMAN SYSTEMS CORPORATION DBA NORTHROP GRUMMAN SYSTEMS CORP
A32ATX

Characteristics

OVERALL LENGTHINCHES NOMINAL 1.720
OVERALL HEIGHTINCHES NOMINAL 0.380
OVERALL WIDTHINCHES NOMINAL 3.780
BODY LENGTHINCHES NOMINAL 1.320
BODY WIDTHINCHES NOMINAL 3.500
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.120
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 1.520
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 2.000
OPERATING TEMP RANGECELSIUS -46.0 TO 75.0
AVERAGE LIFE RATING IN HOURS10000.0
REFERENCE FREQUENCY PER FUNCTIONFOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 640.0
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND BAND PASS 660.0
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION MEGAHERTZ 3RD BAND PASS 680.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST BAND PASS 620.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH BAND PASS 50.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD BAND PASS
VOLTAGE STANDING WAVE RATIO PER FUNCTIONFOURTH FUNCTION 4TH BAND PASS 1.5
VOLTAGE STANDING WAVE RATIO PER FUNCTIONTHIRD FUNCTION 3RD BAND PASS 1.5
VOLTAGE STANDING WAVE RATIO PER FUNCTIONSECOND FUNCTION 2ND BAND PASS 1.5
VOLTAGE STANDING WAVE RATIO PER FUNCTIONFIRST FUNCTION 1ST BAND PASS 1.5
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFOURTH FUNCTION 4TH BAND PASS 5.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND PASS 5.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 5.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 5.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 4
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 4
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 620.00 AND MEGAHERTZ 4TH BAND PASS 639.00 AND MEGAHERTZ 4TH BAND PASS 641.00 AND MEGAHERTZ 4TH BAND PASS 660.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND BAND PASS 640.00 AND MEGAHERTZ 2ND BAND PASS 659.00 AND MEGAHERTZ 2ND BAND PASS 661.00 AND MEGAHERTZ 2ND BAND PASS 680.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST BAND PASS 600.00 AND MEGAHERTZ 1ST BAND PASS 619.00 AND MEGAHERTZ 1ST BAND PASS 621.00 AND MEGAHERTZ 1ST BAND PASS 640.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION MEGAHERTZ 3RD BAND PASS 660.00 AND MEGAHERTZ 3RD BAND PASS 679.00 AND MEGAHERTZ 3RD BAND PASS 681.00 AND MEGAHERTZ 3RD BAND PASS 700.00
BODY MATERIALALUMINUM
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION MEGAHERTZ 3RD BAND PASS 679.00 AND MEGAHERTZ 3RD BAND PASS 681.00
FREQUENCY BAND WIDTH PER FUNCTIONFOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 639.00 AND MEGAHERTZ 4TH BAND PASS 641.00
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND BAND PASS 659.00 AND MEGAHERTZ 2ND BAND PASS 661.00
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST BAND PASS 619.00 AND MEGAHERTZ 1ST BAND PASS 621.00
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 40.0 AND MAXIMUM 1ST BAND PASS 5.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND PASS 40.0 AND MAXIMUM 3RD BAND PASS 5.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFOURTH FUNCTION MINIMUM 4TH BAND PASS 40.0 AND MAXIMUM 4TH BAND PASS 5.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 40.0 AND MAXIMUM 2ND BAND PASS 5.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONTHIRD FUNCTION MEGAHERTZ 3RD BAND PASS 679.0 AND MEGAHERTZ 3RD BAND PASS 681.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONFOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 639.0 AND MEGAHERTZ 4TH BAND PASS 641.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST BAND PASS 619.0 AND MEGAHERTZ 1ST BAND PASS 621.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND BAND PASS 659.0 AND MEGAHERTZ 2ND BAND PASS 661.0
PRECIOUS MATERIAL AND LOCATIONSILVER TER-INAL SURFACES
PRECIOUS MATERIALSILVER
STYLE DESIGNATOR

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
WP01WP01-JUN-07WP81WP
YD01YD01-NOV-16YD81YD
ZU01ZU01-MAY-08ZU81ZU
FXGXDF1C01-JUL-05ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.2000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0690
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
24-AUG-1987
NIIN status code
0

Request a quote