Catalog item

FILTER,BAND PASS

5915FSC
01NCB code
266-7852Item number
NIIN 01-266-7852
Request a quote
Unit price
$29.08
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00209
PINC
0000209
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
30-OCT-87
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$29.081U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$29.081U0N-------$0.00I

Part numbers

Part number
34-2727061-1
CAGE
04655
GENERAL DYNAMICS MISSION SYSTEMS, INC.
CAGE status
A
RNCC
3
RNVC
2
Document availability code
A
RNAAC
TX

Characteristics

OVERALL HEIGHTINCHES NOMINAL 0.780
BODY LENGTHINCHES MAXIMUM 3.800
BODY WIDTHINCHES MAXIMUM 3.250
BODY HEIGHTINCHES MAXIMUM 0.550
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 200.0
OPERATING TEMP RANGECELSIUS -32.0 TO 70.0
END ITEM IDENTIFICATIONMODEM,COMMUNICATIONS MD-1208/G
REFERENCE FREQUENCY PER FUNCTIONFOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 70.0
REFERENCE FREQUENCY PER FUNCTIONSIXTH FUNCTION MEGAHERTZ 6TH BAND PASS 70.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST BAND PASS 70.0
REFERENCE FREQUENCY PER FUNCTIONFIFTH FUNCTION MEGAHERTZ 5TH BAND PASS 70.0
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND BAND PASS 70.0
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION MEGAHERTZ 3RD BAND PASS 70.0
SOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION OHMS 6TH BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH BAND PASS 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION OHMS 5TH BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION OHMS 6TH BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION OHMS 5TH BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH BAND PASS 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND PASS 50.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH BAND PASS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH BAND PASS
VOLTAGE STANDING WAVE RATIO PER FUNCTIONTHIRD FUNCTION 3RD BAND PASS 2.0
VOLTAGE STANDING WAVE RATIO PER FUNCTIONSECOND FUNCTION 2ND BAND PASS 2.0
VOLTAGE STANDING WAVE RATIO PER FUNCTIONFIRST FUNCTION 1ST BAND PASS 2.0
VOLTAGE STANDING WAVE RATIO PER FUNCTIONFOURTH FUNCTION 4TH BAND PASS 2.0
VOLTAGE STANDING WAVE RATIO PER FUNCTIONSIXTH FUNCTION 6TH BAND PASS 2.0
VOLTAGE STANDING WAVE RATIO PER FUNCTIONFIFTH FUNCTION 5TH BAND PASS 2.0
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED STUD(S) 4
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 6.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 6.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND PASS 6.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIFTH FUNCTION 5TH BAND PASS 6.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFOURTH FUNCTION 4TH BAND PASS 6.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSIXTH FUNCTION 6TH BAND PASS 6.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 6
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 6
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN GROUND 4
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION MEGAHERTZ 3RD BAND PASS 68.20 AND MEGAHERTZ 3RD BAND PASS 69.91 AND MEGAHERTZ 3RD BAND PASS 70.09 AND MEGAHERTZ 3RD BAND PASS 71.80
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND BAND PASS 68.20 AND MEGAHERTZ 2ND BAND PASS 69.91 AND MEGAHERTZ 2ND BAND PASS 70.09 AND MEGAHERTZ 2ND BAND PASS 71.80
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST BAND PASS 69.00 AND MEGAHERTZ 1ST BAND PASS 69.95 AND MEGAHERTZ 1ST BAND PASS 70.05 AND MEGAHERTZ 1ST BAND PASS 71.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSIXTH FUNCTION MEGAHERTZ 6TH BAND PASS 65.00 AND MEGAHERTZ 6TH BAND PASS 69.78 AND MEGAHERTZ 6TH BAND PASS 70.22 AND MEGAHERTZ 6TH BAND PASS 75.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 66.50 AND MEGAHERTZ 4TH BAND PASS 69.82 AND MEGAHERTZ 4TH BAND PASS 70.18 AND MEGAHERTZ 4TH BAND PASS 73.50
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIFTH FUNCTION MEGAHERTZ 5TH BAND PASS 64.70 AND MEGAHERTZ 5TH BAND PASS 69.73 AND MEGAHERTZ 5TH BAND PASS 70.27 AND MEGAHERTZ 5TH BAND PASS 75.30
NOMINAL THREAD SIZEINCHES 0.086
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST BAND PASS 69.95 AND MEGAHERTZ 1ST BAND PASS 70.05
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND BAND PASS 69.91 AND MEGAHERTZ 2ND BAND PASS 70.09
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION MEGAHERTZ 3RD BAND PASS 69.91 AND MEGAHERTZ 3RD BAND PASS 70.09
FREQUENCY BAND WIDTH PER FUNCTIONFIFTH FUNCTION MEGAHERTZ 5TH BAND PASS 69.73 AND MEGAHERTZ 5TH BAND PASS 70.27
FREQUENCY BAND WIDTH PER FUNCTIONSIXTH FUNCTION MEGAHERTZ 6TH BAND PASS 69.78 AND MEGAHERTZ 6TH BAND PASS 70.22
FREQUENCY BAND WIDTH PER FUNCTIONFOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 69.82 AND MEGAHERTZ 4TH BAND PASS 70.18
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 30.0 AND MAXIMUM 1ST BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 30.0 AND MAXIMUM 2ND BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND PASS 30.0 AND MAXIMUM 3RD BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIFTH FUNCTION MINIMUM 5TH BAND PASS 30.0 AND MAXIMUM 5TH BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFOURTH FUNCTION MINIMUM 4TH BAND PASS 30.0 AND MAXIMUM 4TH BAND PASS 3.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSIXTH FUNCTION MINIMUM 6TH BAND PASS 30.0 AND MAXIMUM 6TH BAND PASS 3.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONTHIRD FUNCTION MEGAHERTZ 3RD BAND PASS 69.91 AND MEGAHERTZ 3RD BAND PASS 70.09
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONFIFTH FUNCTION MEGAHERTZ 5TH BAND PASS 69.73 AND MEGAHERTZ 5TH BAND PASS 70.27
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONFOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 69.82 AND MEGAHERTZ 4TH BAND PASS 70.18
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONSECOND FUNCTION MEGAHERTZ 2ND BAND PASS 69.91 AND MEGAHERTZ 2ND BAND PASS 70.09
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONSIXTH FUNCTION MEGAHERTZ 6TH BAND PASS 69.78 AND MEGAHERTZ 6TH BAND PASS 70.22
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONFIRST FUNCTION MEGAHERTZ 1ST BAND PASS 69.95 AND MEGAHERTZ 1ST BAND PASS 70.05
SPECIAL FEATURES5 UNFILTERED PIN TERMINALS
STYLE DESIGNATOR

MOE rules

MOE rule
FXGX
MOE CD
DF
AMC
3
AMSC
C
Date assigned
01-JUN-06
IMC
Z
IMCA
SX
PICA
GX
PICA LOA
01
SICA
SX
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
30-OCT-1987
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.