Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
01NCB code
276-8931Item number
NIIN 01-276-8931
Request a quote
Unit price
$6,089.00
Unit of issue
EA
Source of supply
NRP
DEMIL code
D

Identification

Item name code
00765
PINC
0000765
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
7
NIIN assigned
14-APR-88
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030
IUID indicator
Y

Management

Effective date
01-OCT-2026
Major organizational entity
DN
Acquisition advice code
C
Source of supply
NRP
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$6,089.00
Quantity per unit pack
0
Controlled inventory item code
7
Shelf-life code
0
Recoverability code
H
Management control
7H--009
Net price
$2,887.00
USC
L

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
52-464-00133095
SPECTRUM CONTROL INC
A596TXB
8561196-149671
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN DIV LOCKHEED MARTIN
H59ATXB
8561196-111447
L3 TECHNOLOGIES, INC. DIV COMMUNICATION SYSTEMS-EAST
A325ZZ

Characteristics

BODY LENGTHINCHES NOMINAL 2.500
BODY WIDTHINCHES NOMINAL 10.000
BODY HEIGHTINCHES NOMINAL 1.250
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 8.000
OPERATING TEMP RANGECELSIUS -55.0 TO 125.0
END ITEM IDENTIFICATIONCOMMUNICATIONS CENTRAL AN/BSC-1
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSIXTH FUNCTION 6TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 60.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 60.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 60.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFOURTH FUNCTION 4TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIFTH FUNCTION 5TH RADIO INTERFERENCE 400.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSIXTH FUNCTION 6TH RADIO INTERFERENCE 15.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 15.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIFTH FUNCTION 5TH RADIO INTERFERENCE 2.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 2.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 15.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 15.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 3
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION THREADED STUD INPUT 8
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION THREADED STUD OUTPUT 10
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 110.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS DC 4TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 110.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 110.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 110.0
BODY MATERIALMETAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEVOLTS AT SEA LEVEL 220.0
BODY SURFACE TREATMENTTIN
STYLE DESIGNATOR

MOE rules

MOE rule
N2H4
MOE CD
DN
AMC
3
AMSC
H
NIMSC
V
Date assigned
01-AUG-97
IMC
E
PICA
HD
PICA LOA
22
Auth collab
HD
Supp collab
JB GH
DSOR
99
Fmr MOE rl
N9ND

Service data

Navy

COG
7H
IRRC
00
SMCC
9

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
ZZZ0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Unit of issue
EA
TOS
B
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
JV
MIL-PRF-22191, Type III, transparent, waterproof barrier material
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
D
1 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
A

Unit pack

PICA SICA
P
SPC MKG
24
Open for inspection or use only
Inter cont
00
No requirement.
UCL
O
Unit container is not an acceptable shipping container.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
Q
Unit pack weight
3.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
1.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
23-AUG-1989
NIIN status code
0

Request a quote