Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
01NCB code
326-4292Item number
NIIN 01-326-4292
Request a quote
Unit price
$51.65
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00765
PINC
0000765
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
24-SEP-90
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$51.651U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$51.651U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$51.651U0N-------$0.00I

Part numbers

Part number
10VK7
CAGE
05245
TE CONNECTIVITY CORPORATION DIV CORCOM
CAGE status
A
RNCC
3
RNVC
2
Document availability code
E
RNAAC
TX

Characteristics

OVERALL HEIGHTINCHES MAXIMUM 3.710
BODY LENGTHINCHES MAXIMUM 2.250
BODY WIDTHINCHES MAXIMUM 1.280
BODY HEIGHTINCHES MAXIMUM 3.460
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.070
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 1.575
END ITEM IDENTIFICATION0N411089
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 60.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 60.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 10.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 10.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
MAXIMUM TEMP RISECELSIUS 25.0
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 2
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION THREADED STUD GROUND 1
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION THREADED STUD INPUT 2
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION THREADED STUD OUTPUT 2
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 120.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 120.0
BODY MATERIALMETAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEKILOVOLTS AT SEA LEVEL 1.45
SPECIAL FEATURESTWO FILTERED FUNCTIONS
STYLE DESIGNATOR

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZG01ZG01-NOV-98ZG81ZG
FXGXDF3Z01-JUN-06ZSXGX01SX5DGX TUFXTX
N9BNDN3Z01-JUN-06ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.5000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0320
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
26-SEP-1990
NIIN status code
0

Request a quote