Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
01NCB code
331-4073Item number
NIIN 01-331-4073
Request a quote
Unit price
$5,311.10
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00765
PINC
0000765
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
19-DEC-90
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
J
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$5,311.10
Quantity per unit pack
1
Controlled inventory item code
7
Shelf-life code
0
Recoverability code
N
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
A-575323939
THE CAPTOR CORPORATION
A525TX
CNA 2006-0566230
PACIFIC AEROSPACE & ELECTRONICS, LLC
A525TX
WFV357305245
TE CONNECTIVITY CORPORATION DIV CORCOM
A525TX
5006-003613050
SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
A595TX
RF1274213619
EMS DEVELOPMENT CORPORATION DBA EMS DEVELOPMENT CORP
A525TX
841786-113973
LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION
R39ATX

Characteristics

OVERALL LENGTHINCHES MINIMUM 6.590 AND INCHES MAXIMUM 6.650
BODY LENGTHINCHES MINIMUM 5.230 AND INCHES MAXIMUM 5.250
BODY WIDTHINCHES MINIMUM 1.750 AND INCHES MAXIMUM 1.770
BODY HEIGHTINCHES MINIMUM 1.750 AND INCHES MAXIMUM 1.770
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 1.340 AND INCHES MAXIMUM 1.360
OPERATING TEMP RANGECELSIUS -54.0 TO 65.0
AVERAGE LIFE RATING IN HOURS1000.0
END ITEM IDENTIFICATIONTACTICAL AIR OPERATIONS MODULE
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION KILOHMS 3RD RADIO INTERFERENCE 2.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION KILOHMS 1ST RADIO INTERFERENCE 2.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION KILOHMS 2ND RADIO INTERFERENCE 2.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION KILOHMS 4TH RADIO INTERFERENCE 2.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION KILOHMS 4TH RADIO INTERFERENCE 2.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION KILOHMS 3RD RADIO INTERFERENCE 2.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION KILOHMS 2ND RADIO INTERFERENCE 2.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION KILOHMS 1ST RADIO INTERFERENCE 2.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFOURTH FUNCTION 4TH RADIO INTERFERENCE 5000.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 5000.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 5000.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 5000.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 1.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 1.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 1.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 1.0
MAXIMUM VOLTAGE DROP PER FUNCTIONTHIRD FUNCTION MILLIVOLTS AC 3RD RADIO INTERFERENCE 50.0
MAXIMUM VOLTAGE DROP PER FUNCTIONFOURTH FUNCTION MILLIVOLTS AC 4TH RADIO INTERFERENCE 50.0
MAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION MILLIVOLTS AC 1ST RADIO INTERFERENCE 50.0
MAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION MILLIVOLTS AC 2ND RADIO INTERFERENCE 50.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS1.5 AND 3.0 AND 78.0 AND 100.0
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 6
FEATURES PROVIDEDFUNGUS RESISTANT AND SHOCK RESISTANT
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION THREADED STUD INPUT 4
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION THREADED STUD OUTPUT 4
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION THREADED STUD GROUND 2
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 5.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 5.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 5.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 5.0
NOMINAL THREAD SIZEINCHES 0.164
BODY MATERIALMETAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEVOLTS AT SEA LEVEL 500.0
BODY SURFACE TREATMENTTIN
UNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 1.800
SPECIAL FEATURESFOUR FILTERED FUNCTIONS
STYLE DESIGNATOR

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
1
AMSC
C
Date assigned
01-APR-26
PICA
GX
PICA LOA
01
Auth collab
GX

Freight

ACTY CD
TH
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
1.9000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.1480
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
22-DEC-1990
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.