Catalog item

FILTER,BAND SUPPRESSION

5915FSC
01NCB code
334-4791Item number
NIIN 01-334-4791
Request a quote
Unit price
$19,988.87
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
00210
PINC
0000210
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
23-FEB-91
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8527995030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$19,988.871U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$19,988.871U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
1185AS156-130003
NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
A72ATX
40100450545
HENDERSON H F INDUSTRIES
A325TX

Characteristics

OVERALL LENGTHINCHES NOMINAL 8.000
BODY LENGTHINCHES NOMINAL 8.000
BODY WIDTHINCHES NOMINAL 6.000
BODY HEIGHTINCHES NOMINAL 3.500
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.172
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 6.500
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 5.500
OPERATING TEMP RANGECELSIUS -55.0 TO 85.0
REFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND SUPPRESSION 175.0
REFERENCE FREQUENCY PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND SUPPRESSION 175.0
REFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND SUPPRESSION 175.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND SUPPRESSION 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND SUPPRESSION 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND SUPPRESSION 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD BAND SUPPRESSION 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND SUPPRESSION 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND SUPPRESSION 50.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND SUPPRESSION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND SUPPRESSION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD BAND SUPPRESSION
INCLOSURE TYPEENCASED
MOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND SUPPRESSION 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSTHIRD FUNCTION 3RD BAND SUPPRESSION 3.0
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND SUPPRESSION 3.0
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION SCREW INPUT 3
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION SCREW OUTPUT 3
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND SUPPRESSION 100.00 AND KILOHERTZ 2ND BAND SUPPRESSION 150.00 AND KILOHERTZ 2ND BAND SUPPRESSION 200.00 AND KILOHERTZ 2ND BAND SUPPRESSION 250.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND SUPPRESSION 100.00 AND KILOHERTZ 3RD BAND SUPPRESSION 150.00 AND KILOHERTZ 3RD BAND SUPPRESSION 200.00 AND KILOHERTZ 3RD BAND SUPPRESSION 250.00
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND SUPPRESSION 100.00 AND KILOHERTZ 1ST BAND SUPPRESSION 150.00 AND KILOHERTZ 1ST BAND SUPPRESSION 200.00 AND KILOHERTZ 1ST BAND SUPPRESSION 250.00
BODY MATERIALMETAL
FREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND SUPPRESSION 150.00 AND KILOHERTZ 2ND BAND SUPPRESSION 200.00
FREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND SUPPRESSION 150.00 AND KILOHERTZ 1ST BAND SUPPRESSION 200.00
FREQUENCY BAND WIDTH PER FUNCTIONTHIRD FUNCTION KILOHERTZ 3RD BAND SUPPRESSION 150.00 AND KILOHERTZ 3RD BAND SUPPRESSION 200.00
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSTHIRD FUNCTION MINIMUM 3RD BAND SUPPRESSION 3.0 AND MAXIMUM 3RD BAND SUPPRESSION 60.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND SUPPRESSION 3.0 AND MAXIMUM 1ST BAND SUPPRESSION 60.0
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND SUPPRESSION 3.0 AND MAXIMUM 2ND BAND SUPPRESSION 60.0
SPECIAL FEATURESTHREE FILTERED FUNCTIONS; ONE UNFILTERED FUNCTION
STYLE DESIGNATOR
SPECIFICATION/STANDARD DATAMANUFACTURERS SPECIFICATION CONTROL 30003-1185AS156

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZH01ZH01-AUG-95ZH81ZH
N9BNDN3C01-JUN-06ZKEGX01GH5DGXKE GTN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
23-FEB-1991
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.