Catalog item
Request a quoteFILTER,BAND PASS
5915FSC
01NCB code
339-4139Item number
NIIN 01-339-4139
- Unit price
- $23.55
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00209
- PINC
- 0000209
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 22-MAY-91
- Precious metals indicator
- G
- Hazardous material indicator
- P
- Schedule B export code
- 8527995030
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DF | J | SMS | EA | 0.0000 | $23.55 | 1 | U | 0 | N | SF9EH-N | $0.00 | F |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $23.55 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
Characteristics
| OVERALL HEIGHT | INCHES NOMINAL 0.430 |
|---|---|
| BODY LENGTH | INCHES NOMINAL 0.760 |
| BODY WIDTH | INCHES NOMINAL 0.460 |
| BODY HEIGHT | INCHES NOMINAL 0.250 |
| VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 0.300 |
| OPERATING TEMP RANGE | CELSIUS -55.0 TO 125.0 |
| REFERENCE FREQUENCY PER FUNCTION | FOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 70.0 |
| REFERENCE FREQUENCY PER FUNCTION | SECOND FUNCTION MEGAHERTZ 2ND BAND PASS 70.0 |
| REFERENCE FREQUENCY PER FUNCTION | THIRD FUNCTION MEGAHERTZ 3RD BAND PASS 70.0 |
| REFERENCE FREQUENCY PER FUNCTION | FIRST FUNCTION MEGAHERTZ 1ST BAND PASS 70.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | THIRD FUNCTION OHMS 3RD BAND PASS 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FOURTH FUNCTION OHMS 4TH BAND PASS 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST BAND PASS 50.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND BAND PASS 50.0 |
| LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST BAND PASS 50.0 |
| LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND BAND PASS 50.0 |
| LOAD IMPEDANCE PER FUNCTION | FOURTH FUNCTION OHMS 4TH BAND PASS 50.0 |
| LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION OHMS 3RD BAND PASS 50.0 |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD BAND PASS |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND BAND PASS |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | FOURTH FUNCTION 4TH BAND PASS 1.5 |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | THIRD FUNCTION 3RD BAND PASS 1.5 |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | SECOND FUNCTION 2ND BAND PASS 1.5 |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | FIRST FUNCTION 1ST BAND PASS 1.5 |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED TERMINAL 16 |
| FEATURES PROVIDED | MOISTURE RESISTANT AND SHOCK RESISTANT |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | FOURTH FUNCTION 4TH BAND PASS 4.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | THIRD FUNCTION 3RD BAND PASS 4.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | FIRST FUNCTION 1ST BAND PASS 4.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | SECOND FUNCTION 2ND BAND PASS 4.0 |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION PIN OUTPUT 4 |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION PIN INPUT 4 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | FOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 45.00 AND MEGAHERTZ 4TH BAND PASS 68.00 AND MEGAHERTZ 4TH BAND PASS 72.00 AND MEGAHERTZ 4TH BAND PASS 95.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | SECOND FUNCTION MEGAHERTZ 2ND BAND PASS 45.00 AND MEGAHERTZ 2ND BAND PASS 68.00 AND MEGAHERTZ 2ND BAND PASS 72.00 AND MEGAHERTZ 2ND BAND PASS 95.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | THIRD FUNCTION MEGAHERTZ 3RD BAND PASS 45.00 AND MEGAHERTZ 3RD BAND PASS 68.00 AND MEGAHERTZ 3RD BAND PASS 72.00 AND MEGAHERTZ 3RD BAND PASS 95.00 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | FIRST FUNCTION MEGAHERTZ 1ST BAND PASS 45.00 AND MEGAHERTZ 1ST BAND PASS 68.00 AND MEGAHERTZ 1ST BAND PASS 72.00 AND MEGAHERTZ 1ST BAND PASS 95.00 |
| BODY MATERIAL | ALUMINUM |
| FREQUENCY BAND WIDTH PER FUNCTION | THIRD FUNCTION MEGAHERTZ 3RD BAND PASS 68.00 AND MEGAHERTZ 3RD BAND PASS 72.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | FOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 68.00 AND MEGAHERTZ 4TH BAND PASS 72.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | SECOND FUNCTION MEGAHERTZ 2ND BAND PASS 68.00 AND MEGAHERTZ 2ND BAND PASS 72.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | FIRST FUNCTION MEGAHERTZ 1ST BAND PASS 68.00 AND MEGAHERTZ 1ST BAND PASS 72.00 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM 1ST BAND PASS 1.0 AND MAXIMUM 1ST BAND PASS 60.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FOURTH FUNCTION MINIMUM 4TH BAND PASS 1.0 AND MAXIMUM 4TH BAND PASS 60.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | SECOND FUNCTION MINIMUM 2ND BAND PASS 1.0 AND MAXIMUM 2ND BAND PASS 60.0 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | THIRD FUNCTION MINIMUM 3RD BAND PASS 1.0 AND MAXIMUM 3RD BAND PASS 60.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | FIRST FUNCTION MEGAHERTZ 1ST BAND PASS 68.0 AND MEGAHERTZ 1ST BAND PASS 72.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | SECOND FUNCTION MEGAHERTZ 2ND BAND PASS 68.0 AND MEGAHERTZ 2ND BAND PASS 72.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | THIRD FUNCTION MEGAHERTZ 3RD BAND PASS 68.0 AND MEGAHERTZ 3RD BAND PASS 72.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | FOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 68.0 AND MEGAHERTZ 4TH BAND PASS 72.0 |
| BODY SURFACE TREATMENT | NICKEL |
| SPECIAL FEATURES | FOUR FILTERED FUNCTIONS,FOUR UNFILTERED FUNCTION |
| PRECIOUS MATERIAL AND LOCATION | GOLD CONTACT SURFACES |
| PRECIOUS MATERIAL | GOLD |
| STYLE DESIGNATOR |
MOE rules
- MOE rule
- FXGX
- MOE CD
- DF
- AMC
- 3
- AMSC
- C
- Date assigned
- 01-JUN-06
- IMC
- Z
- IMCA
- SX
- PICA
- GX
- PICA LOA
- 01
- SICA
- SX
- SICA LOA
- 5D
- Auth collab
- GX TU
- Fmr MOE rl
- FXTX
Service data
Air Force
- Fund
- SF
- Budget
- 9
- MMAC
- EH
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- TH
- NMFC
- 061990
- NMFC sub
- X
- Uniform freight class
- 58500
- Less than truckload
- P
- Water commodity code
- 593
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELECTRICAL EQUIP:FILTERS
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- NAPPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 88090
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 22-MAY-1991
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.