Catalog item

FILTER,RADIO FREQUENCY INTERFERE

5915FSC
01NCB code
374-1857Item number
NIIN 01-374-1857
Request a quote
Unit price
$7,832.50
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00765
PINC
0000765
Criticality code
Y
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
17-APR-93
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8527995030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSEA0.0000$7,832.50170NSF9EH-N$0.00F
01-OCT-2026DSZSMSEA0.0000$7,832.50170N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
52-576-00233095
SPECTRUM CONTROL INC
A515TX
125A423-203640
LOCKHEED MARTIN CORPORATION DIV ROTARY AND MISSION SYSTEMS
A32ATX
NH125A423-116236
DLA WEAPONS SUPPORT (COLUMBUS) DBA DLA VENDOR ITEM DRAWING (VID) DIV DOCUMENT STANDARDIZATION DIVISION (VA)
A519TX

Characteristics

OPERATING TEMP RANGECELSIUS -55.0 TO 85.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 400.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 2.5
OPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 2.5
OPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 2.5
OPERATING CURRENT RATING PER FUNCTION IN AMPSFIFTH FUNCTION 5TH RADIO INTERFERENCE 3.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSSIXTH FUNCTION 6TH RADIO INTERFERENCE 3.0
OPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 3.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 4TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSIXTH FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 6TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 2ND RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 3RD RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIFTH FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 5TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 1ST RADIO INTERFERENCE
INCLOSURE TYPEENCASED
FEATURES PROVIDEDCABLE ASSEMBLY AND FUNGUS RESISTANT AND SHOCK RESISTANT
FUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION WIRE LEAD OUTPUT 6
FUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION WIRE LEAD INPUT 7
FUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION WIRE LEAD GROUND 1
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSIXTH FUNCTION VOLTS DC 6TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS DC 4TH RADIO INTERFERENCE 28.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 115.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 115.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 115.0
BODY MATERIALALUMINUM
BODY SURFACE TREATMENTTIN
CRITICALITY CODE JUSTIFICATIONFEAT
UNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 1.500
SPECIAL FEATURESNUCLEAR HARDNESS CRITICAL ITEM; SEVEN FUNCTIONS

MOE rules

MOE rule
FXGX
MOE CD
DF
AMC
3
AMSC
C
Date assigned
01-AUG-06
IMC
Z
IMCA
SX
PICA
GX
PICA LOA
01
SICA
SX
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FXTX

Management phrases

Major organizational entity
DS
USC
I
Phrase code
R
Phrase
REFER TO HCI
Quantity per assembly
0
Technical document
HCI

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061990
NMFC sub
X
Uniform freight class
58500
Less than truckload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRICAL EQUIP:FILTERS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
24-APR-1993
NIIN status code
0

Request a quote