Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
024-0863Item number
NIIN 00-024-0863
Request a quote
Unit price
$1,043.85
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
09-OCT-72
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DSJSMSEA0.0000$1,043.851U0N-------$0.00I
01-OCT-2026DFJSMSEA0.0000$1,043.851U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$1,043.851U09B-----$0.00N

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
72-289-1MG674193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H596TA3B
65132105234
THERMO JARRELL ASH CORP BAIRD DIV
A525TA3D
659001CB205234
THERMO JARRELL ASH CORP BAIRD DIV
A325TA3D

Characteristics

ARC QUENCHING METHODMAGNETIC BLOWOUT
BODY WIDTHINCHES MINIMUM 2.240 AND INCHES MAXIMUM 2.260
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.928 AND INCHES MAXIMUM 1.948
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.052 AND INCHES MAXIMUM 2.072
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 2.461 AND INCHES MAXIMUM 2.481
POLE QUANTITY3
THREAD QUANTITY PER INCH32
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
BODY LENGTHINCHES MINIMUM 2.490 AND INCHES MAXIMUM 2.510
BOSS HEIGHTINCHES MINIMUM 0.130 AND INCHES MAXIMUM 0.150
TERMINAL TYPE AND QUANTITYTHREADED STUD 6
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.138
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
UNPACKAGED UNIT WEIGHTOUNCES NOMINAL 14.000
MATERIALCASE PLASTIC
FRAGILITY FACTORMODERATELY RUGGED
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
BODY STYLE
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-APR-06WP81WP
ZH01ZH01-APR-91ZH81ZH
ZR01ZR01-JUL-97ZR81ZR
ZW01ZW01-DEC-95ZW81ZW
FXGXDF5L01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN5L01-APR-06ZGHGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.8000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0150
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.