Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
031-3982Item number
NIIN 00-031-3982
Request a quote
Unit price
$454.04
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
28-OCT-72
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040
FedMall
Y

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
X
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$454.04
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part number
2XAM1516MG3-60-125VDC2
CAGE
74193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
CAGE status
H
RNCC
3
RNVC
9
Document availability code
E
RNAAC
TX
RNFC
3
RNSC
D

Characteristics

ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
BODY STYLE
BODY LENGTHINCHES MINIMUM 3.709 AND INCHES MAXIMUM 3.729
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS DC 2000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 2
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.740 AND INCHES MAXIMUM 0.760
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 1.021 AND INCHES MAXIMUM 1.041
FRAGILITY FACTORMODERATELY RUGGED
BOSS HEIGHTINCHES MINIMUM 0.146 AND INCHES MAXIMUM 0.166
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 3.239
POLE QUANTITY2
ARC QUENCHING METHODMAGNETIC BLOWOUT
BODY WIDTHINCHES MINIMUM 2.021 AND INCHES MAXIMUM 2.041
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 3.053 AND INCHES MAXIMUM 3.073
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 1.021 AND INCHES MAXIMUM 1.041
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.600 AND MAXIMUM AT 200 PCT 8.000
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES DC 60.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS DC 125.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
MATERIALCASE PLASTIC
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTAB W/SCREW 4
NOMINAL THREAD SIZEINCHES 0.138
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
3
AMSC
L
Date assigned
01-NOV-25
PICA
GX
PICA LOA
01
Auth collab
GX

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.