Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
173-7156Item number
NIIN 00-173-7156
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
320P33544940
CUMMINS POWER GENERATION INC.
AC15TX3D
MP103A76374
SAFRAN ELECTRICAL & POWER USA, LLC DBA LABINAL POWER SYSYEMS USE CAGE CODE 81640 FOR CATALOGING
RC16TX3D
104-215-10179405
WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC
HC15TX3D
436-215-10179405
WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC
HC15TX3D
MILC580981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX3D
D6752-2-1582647
SENSATA TECHNOLOGIES, INC. DIV SENSATA ATTLEBORO
AC13TX3D
102-000993742
DRS NAVAL POWER SYSTEMS INC DBA DRS POWER & CONTROL TECHNOLOGIES INC
AC15TX3D
MS25017-1596906
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D

Characteristics

CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 15.0 AND AMPERES DC 15.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 115.0 AND DC 28.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 3500.0 AND DC 6000.0
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYSCREW 2
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-5809
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 15.000 AND MAXIMUM AT 200 PCT 55.000 AND MINIMUM AT 400 PCT 2.000 AND MAXIMUM AT 400 PCT 7.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND EXPLOSION RESISTANT
TRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
FREQUENCY IN HERTZ400.0
BODY LENGTHINCHES MAXIMUM 2.189
BODY WIDTHINCHES MAXIMUM 0.750
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.188
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MAXIMUM 2.189
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.000
POLE QUANTITY1
ACTUATOR POSITION DESIGNATIONAT POLE ONE
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.138
BODY STYLE
BUSHING LENGTHINCHES NOMINAL 0.250
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
ACTUATOR FUNCTIONTRIP-RESET
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
RESET METHODMANUAL
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
TRIP RELEASE METHODSINGLE LOCATION THERMAL

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedAcquisition advice codePICAPICA LOAAuth collab
WB01WB01-FEB-05WB81WB
YA01YA01-AUG-00YA81YA
YB01YB01-APR-91YB81YB
YD01YD01-AUG-16YD81YD
YJ01YJ01-APR-91YJ81YJ
YW01YW01-AUG-97YW81YW
YY01YY01-FEB-15YY81YY
ZF01ZF01-MAR-00ZF81ZF
ZH01ZH01-APR-91ZH81ZH
ZI01ZI01-NOV-20ZI81ZI
ZJ01ZJ01-MAR-25ZJ81ZJ
ZP01ZP01-APR-91ZP81ZP
ZR01ZR01-APR-91ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-05ZW81ZW
G860T10001-APR-91C864875 86
VJ01VJ01-FEB-19VJ81VJ

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
XX
Cush dun
XX
THK
X
Unit cont
XX
PKG data source
A

Unit pack

PICA SICA
P
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0090
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
09-NOV-1990
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59255925-00-173-7161501-JUL-2026A
59255925-00-686-0292501-JUL-2026A

Request a quote