Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
229-1412Item number
NIIN 00-229-1412
Request a quote
Unit price
$273.41
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
07-FEB-69
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$273.411U0NSF9EH-V$0.00F
01-OCT-2026DSJSMSEA0.0000$273.411U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCRNJC
3MC1-3-32V320
FLAME ENTERPRISES, INC. DBA FLAME ENTERPRISES INC
A525ZZ
3MC1-3-373803
TEXAS INSTRUMENTS INC METALLURGICAL MATERIALS DIV
A394TA3D1
3MC1-3-382647
SENSATA TECHNOLOGIES, INC. DIV SENSATA ATTLEBORO
A596TX3B
9131C2001-287557
LOCKHEED CORP LOCKHEED ELECTRONICS CO INC
H595BF3B
531365-796214
RAYTHEON COMPANY DBA RAYTHEON
A595TXB
4V94019-113A98897
LOCKHEED MARTIN CORP DIV LOCKHEED MARTIN AERONAUTICS COMPANY
A322TA3D
5925002291412A00AM
E.C.A ETABLISSEMENT CENTRAL DES APPROVISIONNEMENTS DES FORCES ARMEES ROYALES
A699YP4B
11731117-219200
COMBAT CAPABILITIES DEVELOPMENT COMMAND (CCDC) ARMAMENTS CENTER DBA CCDC DIV LOGISTICS RESEARCH AND ENGINEERING DIRECTORATE
A595TX3B

Characteristics

TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.500 AND MAXIMUM AT 200 PCT 0.800
NOMINAL THREAD SIZEINCHES 0.469
TERMINAL TYPE AND QUANTITYSCREW 2
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 1.669
POLE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 3.0 AND AMPERES DC 3.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 115.0 AND DC 28.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 1000.0 AND DC 2500.0
MANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONE
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNS
BODY STYLE
BUSHING LENGTHINCHES NOMINAL 0.548
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
TRIP RELEASE METHODSINGLE LOCATION MAGNETIC
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT135.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
BODY LENGTHINCHES NOMINAL 1.781
BODY WIDTHINCHES NOMINAL 0.656
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.688
FREQUENCY IN HERTZ400.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
YP01YP01-JUL-10YP81YP
ZH01ZH01-APR-91ZH81ZH
ZK01ZK01-JUL-00ZK81ZK
FXGXDF2C01-JUL-05ZSXGX01SX5DGX TUFXTX
VJ01VJ01-DEC-18VJ81VJ

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
SG
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
2.30000
UP SZ MAXL
2.80000
UP SZ MAXH
1.60000
Unit pack cube
0.0050
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
27-JUN-1980
NIIN status code
0

Cancelled and replaced NIINs

FSC
5925
Cancelled NIIN
5925-00-796-0671
NIIN status code
7
Effective date
01-JUL-2026
DEMIL code
A

Request a quote