Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
00NCB code
459-9002Item number
NIIN 00-459-9002
- Unit price
- $597.37
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 02-JAN-70
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | X | SMS | EA | 0.0000 | $597.37 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | X | SMS | EA | 0.0000 | $597.37 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
Characteristics
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 3.239 |
|---|---|
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 2.750 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 1.031 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 1.031 |
| CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 2.939 |
| BODY STYLE | |
| BODY LENGTH | INCHES NOMINAL 3.719 |
| BODY WIDTH | INCHES NOMINAL 3.052 |
| ULTIMATE TRIP TIME PER POLE IN SECONDS | ALL LOCATIONS MINIMUM 150.000 AND MAXIMUM 500.000 |
| RESET METHOD | MANUAL |
| POLE QUANTITY | 3 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| BOSS HEIGHT | INCHES NOMINAL 0.156 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES AC 1.4 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 480.0 |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS MINIMUM AT 200 PCT 40.000 AND MAXIMUM AT 200 PCT 100.000 AND MINIMUM AT 300 PCT 10.000 AND MAXIMUM AT 105 PCT 30.000 AND MINIMUM AT 400 PCT 6.000 AND MAXIMUM AT 400 PCT 18.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| FREQUENCY IN HERTZ | 60.0 |
| MATERIAL | CASE PLASTIC |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 1200.0 |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 3 |
| TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS TIME DELAY |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| TERMINAL TYPE AND QUANTITY | THREADED STUD 6 |
| THREAD QUANTITY PER INCH | 32 |
| EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
| INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS SERIES TRIP |
| NOMINAL THREAD SIZE | INCHES 0.138 |
| TRIP RELEASE METHOD | ALL LOCATIONS MAGNETIC-HYDRAULIC |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 6 |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZU01 | ZU | 01-APR-91 | ZU | 81 | ZU | ||||||||
| N9BN | DN | 0 | 0 | 01-APR-06 | Z | HD | GX | 01 | GH | 5D | GX | HD | N9ND |
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- HD
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69FZ
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- XXX
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0320
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- TX
- Dt stdzn dec
- 17-JUL-1970
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.