Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
465-9743Item number
NIIN 00-465-9743
Request a quote
Unit price
$294.99
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
19-JAN-70
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$294.991U0ZQ2200X-$0.00A
01-OCT-2026DSJSMSEA0.0000$294.991U0N-------$0.00I

Part numbers

Part number
71-212-4MG6
CAGE
74193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
CAGE status
H
RNCC
3
RNVC
9
Document availability code
5
RNAAC
CT
RNFC
3
RNSC
D

Characteristics

SWITCH CURRENT RATING AND TYPE IN AMPSAC 5.0 AND DC 1.0
POLE QUANTITY2
ARC QUENCHING METHODMAGNETIC BLOWOUT
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 2.549 AND INCHES MAXIMUM 2.673
BODY STYLE
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 2
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.138
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE TWO
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
BOSS HEIGHTINCHES NOMINAL 0.140
BODY LENGTHINCHES NOMINAL 2.500
BODY WIDTHINCHES NOMINAL 1.500
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.938
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.750
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
SWITCH TERMINAL TYPETAB, SOLDER LUG
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.750
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTHREADED STUD 4
TRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS
FREQUENCY IN HERTZ50.0 OR 60.0
MATERIALCASE PLASTIC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1000.0
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.062
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 125.0 AND DC 50.0
UNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 0.547
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 28.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 208.0
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT

MOE rules

MOE rule
A918
MOE CD
DA
AMC
3
AMSC
H
Date assigned
01-APR-06
IMC
Z
IMCA
CD
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Supp collab
CL
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.6000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0460
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
17-JUL-1970
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.