Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
521-8208Item number
NIIN 00-521-8208
Request a quote
Unit price
$781.33
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
Z
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$781.33
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
74-648-12-1-2-674193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H395TX3D
74-648-12-5-674193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H595TX3B
74-648-12 1-2 674193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H595TX3B
61315-698897
LOCKHEED MARTIN CORP DIV LOCKHEED MARTIN AERONAUTICS COMPANY
A5259ZD
DMS83059B16236
DLA WEAPONS SUPPORT (COLUMBUS) DBA DLA VENDOR ITEM DRAWING (VID) DIV DOCUMENT STANDARDIZATION DIVISION (VA)
A596TX

Characteristics

DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
ACTUATOR POSITION DESIGNATIONAT EACH POLE
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 12.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 200.0
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.802 AND INCHES MAXIMUM 1.822
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
ACTUATOR FUNCTIONTRIP-RESET
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
ULTIMATE TRIP TIME PER POLE IN SECONDSALL LOCATIONS NOMINAL 300.000
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 1.990 AND INCHES MAXIMUM 2.010
POLE QUANTITY3
ARC QUENCHING METHODAIR
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
NOMINAL THREAD SIZEINCHES 0.138
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS NOMINAL AT 200 PCT 80.000 AND NOMINAL AT 300 PCT 25.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDEXPLOSION RESISTANT
FREQUENCY IN HERTZ480.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
BODY STYLE
BODY LENGTHINCHES MINIMUM 2.490 AND INCHES MAXIMUM 2.510
BODY WIDTHINCHES MINIMUM 2.263 AND INCHES MAXIMUM 2.283
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.180 AND INCHES MAXIMUM 1.200
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TERMINAL TYPE AND QUANTITYTHREADED STUD 6
FRAGILITY FACTORMODERATELY RUGGED
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1500.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collabSupp collabFmr MOE rl
ZR01ZR01-APR-91ZR81ZR
ZU01ZU01-APR-91ZU81ZU
DGX1DS3Z01-AUG-06GX01GXTXDTX1
VJ01VJ01-FEB-19VJ81VJ

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
E5
ASTM D5118/D5118M, fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.3000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
10-MAY-1971
NIIN status code
0

Cancelled and replaced NIINs

FSC
5925
Cancelled NIIN
5925-00-503-6419
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote