Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
879-9567Item number
NIIN 00-879-9567
Request a quote
Unit price
$1,014.09
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
17-NOV-67
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$1,014.091U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$1,014.091U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$1,014.091U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
AT33200NS24446
GENERAL ELECTRIC COMPANY
A596TX3B
TQD32200WLWTQD225S60969
GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL
A59ETX3B
AT33200NS60969
GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL
A52ETX3D
TQD32200WL/TQD225S60969
GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL
A32EZZ
CCS20071183
BRYANT ELECTRIC
A596TX3B
SCA3200WSQCC89946
EATON CORPORATION DBA EATON INOAC
A526TX3D

Characteristics

INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 75.000 AND MAXIMUM AT 200 PCT 325.000
ACTUATOR FUNCTIONTRIP-RESET
BODY STYLE
BODY LENGTHINCHES NOMINAL 6.562
BODY WIDTHINCHES NOMINAL 4.125
BODY HEIGHTINCHES NOMINAL 2.594
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 6.250
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 1.375
ACTUATOR POSITION DESIGNATIONAT POLE TWO
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
POLE QUANTITY3
MOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 4
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 200.0
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS AND TIME DELAY
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 240.0
FREQUENCY IN HERTZ60.0
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.250
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 4.880
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.375
BOSS HEIGHTINCHES NOMINAL 0.219
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE THREE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 10000.0
MATERIALCASE PLASTIC
TRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 50.0
SWITCH TERMINAL TYPEWIRE LEAD
SWITCH CURRENT RATING AND TYPE IN AMPSAC 225.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
TERMINAL TYPE AND QUANTITYCOMPRESSION 6

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
A918DA1H01-APR-06ZCDGX01CD5DCD GXCE AZA196
FXGXDF1H01-APR-06ZSXGX01SX5DGX TUFXTX

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
42
Container, watervaporproof bag, heat sealed, container
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
EA
MIL-DTL-17667, neutral wrapping paper
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
22.2000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
2.6480
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
15-DEC-1974
NIIN status code
0

Cancelled and replaced NIINs

FSC
5925
Cancelled NIIN
5925-00-242-2272
NIIN status code
7
Effective date
01-JUL-2026
DEMIL code
A

Request a quote