Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
946-4568Item number
NIIN 00-946-4568
Request a quote
Unit price
$53.04
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
18-MAR-66
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$53.041U0ZQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$53.041U0NSF9EH-V$0.00F
01-OCT-2026DNZSMSEA0.0000$53.041U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$53.041U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
MIL-C-580981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
MS26574-3/496906
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
MS26574-3/40U583
SAE INTERNATIONAL DBA SAE INTERNATIONAL
A32EZZ
SAE-AS580910U583
SAE INTERNATIONAL DBA SAE INTERNATIONAL
A31EZZ

Characteristics

THREAD SERIES DESIGNATORUN
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-5809
RESET METHODMANUAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION MILLIAMPERES AC 750.0 AND MILLIAMPERES DC 750.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 115.0 AND DC 28.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 5000.0 AND DC 5000.0
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
BODY LENGTHINCHES MAXIMUM 0.780
TRIP RELEASE METHODSINGLE LOCATION THERMAL
ACTUATOR FUNCTIONTRIP-RESET
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.593
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSTANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). 96906--S26574
TRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
TERMINAL TYPE AND QUANTITYTAB W/SCREW 2
POLE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD QUANTITY PER INCH32
BODY WIDTHINCHES MAXIMUM 0.539
UNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 0.066
FREQUENCY IN HERTZ400.0
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
NOMINAL THREAD SIZEINCHES 0.438
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDCORROSION RESISTANT AND DUSTPROOF AND EXPLOSION PROOF AND FUNGUS RESISTANT AND MOISTURE RESISTANT AND SAND RESISTANT AND VIBRATION RESISTANT
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
ACTUATOR POSITION DESIGNATIONAT POLE ONE
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
BODY STYLE
BUSHING LENGTHINCHES NOMINAL 0.250
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.525
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT145.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-OCT-00YA81YA
YD01YD01-AUG-16YD81YD
ZC01ZC01-APR-91ZC81ZC
ZG01ZG01-OCT-09ZG81ZG
ZJ01ZJ01-APR-25ZJ81ZJ
ZK01ZK01-APR-91ZK81ZK
ZW01ZW01-DEC-05ZW81ZW
A918DA1T01-APR-06ZCDGX01CD5DCD GXBD AJ CLA196
FXGXDF1T01-APR-06ZSXGX01SX5DGX TUFXTX
G920T10001-MAY-19C924875 92
G940T10001-APR-91C944875 94
N9BNDN1T01-APR-06ZGHGX01GH5DGXKE GT HDN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0150
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5925-01-054-34533TX06-NOV-20050
3TX06-NOV-20050
1TX06-NOV-20050

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59255925-00-939-6871502-JUL-2026A
59255925-00-898-9361502-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.