Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
972-3000Item number
NIIN 00-972-3000
Request a quote
Unit price
$3,355.12
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-61
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNZSMSEA0.0000$3,355.121U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$3,355.121U0-------$0.00I
01-OCT-2026GPZSMSEA0.0000$3,355.121U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
9985030086
L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC. DBA SPD ELECTRICAL SYSTEMS, INC.
A32ATX3D
ETN277430086
L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC. DBA SPD ELECTRICAL SYSTEMS, INC.
A526TX3D
845799-249956
RAYTHEON COMPANY DIV CORP
AC16ZZAC
458D510G1579500
WESTINGHOUSE ELECTRIC CORP
A52ETX3D
AQB-A101-100H81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
AQB-A101-100H89946
EATON CORPORATION DBA EATON INOAC
A525ZZ
ETN277489946
EATON CORPORATION DBA EATON INOAC
AC16ZZAC
5925PL09949459009H
JEDNOLITY INDEKS MATERIALOWY - UNIFORM MATERIAL INDEX
A699WP4B
5L.4831.012.60D1901
HENSOLDT SENSORS GMBH DIV SEPS
A523ZG4A

Characteristics

BODY WIDTHINCHES NOMINAL 4.125
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS NOMINAL AT 250 PCT 3600.000
ACTUATOR FUNCTIONTRIP-RESET
BODY HEIGHTINCHES NOMINAL 3.875
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
BODY LENGTHINCHES NOMINAL 6.500
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 3.938
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 100.0 AND AMPERES DC 100.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 500.0 AND DC 250.0
POLE QUANTITY3
NOMINAL THREAD SIZEINCHES 0.190
MOUNTING FACILITY TYPE AND QUANTITYTHREADED STUD(S) 6
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 1.344
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 3.312
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 3.688
FRAGILITY FACTORMODERATELY RUGGED
BOSS HEIGHTINCHES NOMINAL 0.188
TRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
SPECIAL HANDLING FEATUREMAGNETIC
TRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 50.0
FREQUENCY IN HERTZ400.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNF
ACTUATOR POSITION DESIGNATIONAT POLE TWO
THREAD QUANTITY PER INCH32
TERMINAL TYPE AND QUANTITYTHREADED STUD 6
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT135.0
RESET METHODMANUAL
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
BODY STYLE
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 15000.0 AND DC 10000.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JUN-07WP81WP
WU01WU01-MAY-15WU81WU
YB01YB01-APR-91YB81YB
ZA01ZA01-APR-91ZA81ZA
ZB01ZB01-APR-91ZB81ZB
ZC01ZC01-APR-91ZC81ZC
ZG01ZG01-APR-91ZG81ZG
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZN01ZN01-APR-91ZN81ZN
ZK01ZK01-APR-91ZK81ZK
ZP01ZP01-JUL-09ZP81ZP
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
C911GP1R01-APR-06GX01XG5DXG GXC007
N9BNDN1R01-APR-06ZGHGX01GH5DGXHD JB HX GTN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
01F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
GB
MIL-PRF-121, greaseproof, waterproof barrier
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
6.9000
UP SZ MAXB
6.00000
UP SZ MAXL
9.00000
UP SZ MAXH
5.00000
Unit pack cube
0.1560
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
15-DEC-1974
NIIN status code
0

Cancelled and replaced NIINs

FSC
5925
Cancelled NIIN
5925-00-086-9283
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.