Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
153-7491Item number
NIIN 01-153-7491
- Unit price
- $257.96
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 16-MAY-83
- Precious metals indicator
- A
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
- FedMall
- Y
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- J
- Source of supply
- SMS
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $257.96
- Quantity per unit pack
- 1
- Controlled inventory item code
- U
- Shelf-life code
- 0
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
Characteristics
| BODY STYLE | |
|---|---|
| BODY LENGTH | INCHES NOMINAL 2.500 |
| BODY WIDTH | INCHES MINIMUM 2.060 AND INCHES MAXIMUM 2.070 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 1.938 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 0.750 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 2.062 |
| SWITCH CONTACT ARRANGEMENT | DOUBLE POLE, DOUBLE THROW |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 0.750 |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| BOSS HEIGHT | INCHES NOMINAL 0.140 |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MINIMUM 2.409 AND INCHES MAXIMUM 2.533 |
| POLE QUANTITY | 4 |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 8 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| SPECIAL HANDLING FEATURE | MAGNETIC |
| THREAD QUANTITY PER INCH | 32 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | THIRD LOCATION AMPERES AC 30.0 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | FIRST LOCATION AMPERES AC 30.0 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SECOND LOCATION AMPERES AC 30.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SECOND LOCATION AC 250.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | FOURTH LOCATION DC 102.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | THIRD LOCATION AC 250.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | FIRST LOCATION AC 250.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | FOURTH LOCATION DC 2000.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SECOND LOCATION AC 1000.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | FIRST LOCATION AC 1000.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | THIRD LOCATION AC 1000.0 |
| CIRCUIT PROTECTION TYPE | SECOND LOCATION OVERCURRENT |
| CIRCUIT PROTECTION TYPE | FIRST LOCATION OVERCURRENT |
| CIRCUIT PROTECTION TYPE | THIRD LOCATION OVERCURRENT |
| CIRCUIT PROTECTION TYPE | FOURTH LOCATION UNDERVOLTAGE |
| TRIP RELEASE METHOD | ALL LOCATIONS MAGNETIC-HYDRAULIC |
| TRIP RELEASE CHARACTERISTIC | SECOND LOCATION TIME DELAY |
| TRIP RELEASE CHARACTERISTIC | THIRD LOCATION TIME DELAY |
| TRIP RELEASE CHARACTERISTIC | FIRST LOCATION TIME DELAY |
| TRIP RELEASE CHARACTERISTIC | FOURTH LOCATION INSTANTANEOUS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 4 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, AND FOUR LINKED |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | ALARM 2 |
| INTERNAL TRIP RELEASE CONFIGURATION | FIRST LOCATION SERIES TRIP |
| INTERNAL TRIP RELEASE CONFIGURATION | SECOND LOCATION SERIES TRIP |
| INTERNAL TRIP RELEASE CONFIGURATION | THIRD LOCATION SERIES TRIP |
| INTERNAL TRIP RELEASE CONFIGURATION | FOURTH LOCATION RELAY TRIP |
| NOMINAL THREAD SIZE | INCHES 0.138 |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE TWO AND INTERNAL AT POLE THREE |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | THIRD LOCATION MINIMUM AT 200 PCT 3.000 AND MAXIMUM AT 200 PCT 11.000 |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | FIRST LOCATION MINIMUM AT 200 PCT 3.000 AND MAXIMUM AT 200 PCT 11.000 |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SECOND LOCATION MINIMUM AT 200 PCT 3.000 AND MAXIMUM AT 200 PCT 11.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
| SWITCH CURRENT RATING AND TYPE IN AMPS | AC 10.0 AND DC 4.0 |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 250.0 AND DC 30.0 |
| UNPACKAGED UNIT WEIGHT | OUNCES NOMINAL 12.500 |
| FREQUENCY IN HERTZ | 50.0 OR 60.0 |
| MATERIAL | CASE PLASTIC |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| TERMINAL TYPE AND QUANTITY | THREADED STUD 8 |
MOE rules
- MOE rule
- DGX1
- MOE CD
- DS
- AMC
- 3
- AMSC
- C
- Date assigned
- 01-NOV-25
- PICA
- GX
- PICA LOA
- 01
- Auth collab
- GX
Freight
- ACTY CD
- TX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- XXX
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.9000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0280
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 96250
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 16-MAY-1983
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.