Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
153-7491Item number
NIIN 01-153-7491
Request a quote
Unit price
$257.96
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
16-MAY-83
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
FedMall
Y

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
J
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$257.96
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSCSADC
AM4-Z101-174193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H596TXB
AM4-A8A2A2A18-A74193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H39ETX
0N286855-198230
NATIONAL SECURITY AGENCY
AC16ZZAC

Characteristics

BODY STYLE
BODY LENGTHINCHES NOMINAL 2.500
BODY WIDTHINCHES MINIMUM 2.060 AND INCHES MAXIMUM 2.070
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.938
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.750
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.062
SWITCH CONTACT ARRANGEMENTDOUBLE POLE, DOUBLE THROW
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.750
FRAGILITY FACTORMODERATELY RUGGED
BOSS HEIGHTINCHES NOMINAL 0.140
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 2.409 AND INCHES MAXIMUM 2.533
POLE QUANTITY4
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 8
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLETHIRD LOCATION AMPERES AC 30.0
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEFIRST LOCATION AMPERES AC 30.0
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESECOND LOCATION AMPERES AC 30.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSECOND LOCATION AC 250.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSFOURTH LOCATION DC 102.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSTHIRD LOCATION AC 250.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSFIRST LOCATION AC 250.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSFOURTH LOCATION DC 2000.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSECOND LOCATION AC 1000.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSFIRST LOCATION AC 1000.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSTHIRD LOCATION AC 1000.0
CIRCUIT PROTECTION TYPESECOND LOCATION OVERCURRENT
CIRCUIT PROTECTION TYPEFIRST LOCATION OVERCURRENT
CIRCUIT PROTECTION TYPETHIRD LOCATION OVERCURRENT
CIRCUIT PROTECTION TYPEFOURTH LOCATION UNDERVOLTAGE
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICSECOND LOCATION TIME DELAY
TRIP RELEASE CHARACTERISTICTHIRD LOCATION TIME DELAY
TRIP RELEASE CHARACTERISTICFIRST LOCATION TIME DELAY
TRIP RELEASE CHARACTERISTICFOURTH LOCATION INSTANTANEOUS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 4
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, THREE, AND FOUR LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 2
INTERNAL TRIP RELEASE CONFIGURATIONFIRST LOCATION SERIES TRIP
INTERNAL TRIP RELEASE CONFIGURATIONSECOND LOCATION SERIES TRIP
INTERNAL TRIP RELEASE CONFIGURATIONTHIRD LOCATION SERIES TRIP
INTERNAL TRIP RELEASE CONFIGURATIONFOURTH LOCATION RELAY TRIP
NOMINAL THREAD SIZEINCHES 0.138
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE TWO AND INTERNAL AT POLE THREE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTTHIRD LOCATION MINIMUM AT 200 PCT 3.000 AND MAXIMUM AT 200 PCT 11.000
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTFIRST LOCATION MINIMUM AT 200 PCT 3.000 AND MAXIMUM AT 200 PCT 11.000
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSECOND LOCATION MINIMUM AT 200 PCT 3.000 AND MAXIMUM AT 200 PCT 11.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
SWITCH TERMINAL TYPETAB, SOLDER LUG
SWITCH CURRENT RATING AND TYPE IN AMPSAC 10.0 AND DC 4.0
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 250.0 AND DC 30.0
UNPACKAGED UNIT WEIGHTOUNCES NOMINAL 12.500
FREQUENCY IN HERTZ50.0 OR 60.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTHREADED STUD 8

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
3
AMSC
C
Date assigned
01-NOV-25
PICA
GX
PICA LOA
01
Auth collab
GX

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.9000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0280
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
96250

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
16-MAY-1983
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.