Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
160-2855Item number
NIIN 01-160-2855
Request a quote
Unit price
$1,580.88
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
19-AUG-83
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$1,580.881U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$1,580.881U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,580.881U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
G166010-23B150
RAYTHEON COMPANY DBA RAYTHEON CO
A32ATX
CD4-Z296-1W3AQ68
HEINEMANN ELECTRIC CANADA LTD DIVOF EATON CORP
H595ZZB
G166010-249956
RAYTHEON COMPANY DIV CORP
A59ATXB
G166010-254X10
RAYTHEON COMPANY
A525ZZ
CD4-Z160-274193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H596TXB
CD4-Z296-1W74193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H595ZZB
CD4-Z296-1WL3330
HEINEMANN ELECTRIC CANADA INCDIVISION OF EATON CORP
A525ZZ

Characteristics

BODY STYLE
BODY LENGTHINCHES NOMINAL 5.844
BODY WIDTHINCHES NOMINAL 3.096
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 3.546
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 1.032
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.750
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.031
BOSS HEIGHTINCHES NOMINAL 0.218
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.609
POLE QUANTITY4
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 8
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 90.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSFIRST LOCATION AC 120.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSTHIRD LOCATION AC 240.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSECOND LOCATION AC 240.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSFOURTH LOCATION AC 240.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 5000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICFOURTH LOCATION TIME DELAY
TRIP RELEASE CHARACTERISTICSECOND LOCATION TIME DELAY
TRIP RELEASE CHARACTERISTICFIRST LOCATION INSTANTANEOUS
TRIP RELEASE CHARACTERISTICTHIRD LOCATION TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 4
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, THREE, AND FOUR LINKED
INTERNAL TRIP RELEASE CONFIGURATIONFIRST LOCATION RELAY TRIP
INTERNAL TRIP RELEASE CONFIGURATIONFOURTH LOCATION SERIES TRIP
INTERNAL TRIP RELEASE CONFIGURATIONTHIRD LOCATION SERIES TRIP
INTERNAL TRIP RELEASE CONFIGURATIONSECOND LOCATION SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.138
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTTHIRD LOCATION MINIMUM AT 200 PCT 4.000 AND MAXIMUM AT 200 PCT 10.000
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTFOURTH LOCATION MINIMUM AT 200 PCT 4.000 AND MAXIMUM AT 200 PCT 10.000
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSECOND LOCATION MINIMUM AT 200 PCT 4.000 AND MAXIMUM AT 200 PCT 10.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDSHOCK RESISTANT AND VIBRATION RESISTANT
FREQUENCY IN HERTZ400.0
FREQUENCY IN HERTZ440.0
MATERIALCASE PLASTIC
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 49956-G166010
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTHREADED STUD 10

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WG01WG01-OCT-17WG81WG
ZU01ZU01-MAY-08ZU81ZU
FXGXDF1C01-JUL-05ZSXGX01SX5DGX TUFXTX
N9BNDN1C01-DEC-13ZGHGX01GH5DGXGG

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
42
Container, watervaporproof bag, heat sealed, container
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
EA
MIL-DTL-17667, neutral wrapping paper
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
3.7000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.3650
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
19-AUG-1983
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.