Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
216-2172Item number
NIIN 01-216-2172
Request a quote
Unit price
$1,474.21
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
07-SEP-85
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$1,474.211U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,474.211U0-------$0.00I

Part numbers

Part number
AP-12-1RC-65F-203
CAGE
81541
SENSATA TECHNOLOGIES MARYLAND, INC
CAGE status
A
RNCC
3
RNVC
2
Document availability code
E
RNAAC
TX

Characteristics

THREAD PITCH DIAMETERSINCHES 0.3503 TO 0.3537
BODY STYLE
BUSHING LENGTHINCHES MAXIMUM 0.380
BODY LENGTHINCHES MAXIMUM 1.500
BODY WIDTHINCHES MAXIMUM 1.250
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.860 AND INCHES MAXIMUM 0.890
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.610 AND INCHES MAXIMUM 0.640
NONTURN DEVICE RADIUSINCHES MINIMUM 0.610 AND INCHES MAXIMUM 0.640
NONTURN DEVICE LENGTHINCHES NOMINAL 0.130
NONTURN DEVICE DIAMETERINCHES MINIMUM 0.235 AND INCHES MAXIMUM 0.265
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.780
POLE QUANTITY2
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 20.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.375
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE TWO
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 1.200 AND MAXIMUM AT 200 PCT 7.500
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT
SWITCH TERMINAL TYPEWIRE HOOK
SWITCH CURRENT RATING AND TYPE IN AMPSAC 0.5 AND DC 0.5
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 120.0 AND DC 50.0
UNPACKAGED UNIT WEIGHTOUNCES NOMINAL 3.600
FREQUENCY IN HERTZ60.0
THREAD SERIES DESIGNATORUNEF
TERMINAL TYPE AND QUANTITYWIRE HOOK 4

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
3
AMSC
C
Date assigned
01-APR-06
IMC
Z
IMCA
HD
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
HD
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
10055

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
07-SEP-1985
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.