Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
226-8318Item number
NIIN 01-226-8318
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
24-FEB-86
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040

Part numbers

Part number
ETN583610S36
CAGE
30086
L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC. DBA SPD ELECTRICAL SYSTEMS, INC.
CAGE status
A
RNCC
3
RNVC
2
Document availability code
E
RNAAC
TX

Characteristics

BODY STYLE
BODY LENGTHINCHES NOMINAL 11.000
BODY WIDTHINCHES NOMINAL 9.000
BODY HEIGHTINCHES NOMINAL 4.625
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 9.875
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 3.000
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.250
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 9.875
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 3.000
BOSS HEIGHTINCHES NOMINAL 0.219
POLE QUANTITY3
MOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 6
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 250.0 AND AMPERES DC 250.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 500.0 AND DC 250.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 20000.0 AND DC 10000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS AND TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT140.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE TWO
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 600 PCT 20.000 AND MAXIMUM AT 600 PCT 32.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE
TRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 50.0
SWITCH TERMINAL TYPEWIRE LEAD
SWITCH CURRENT RATING AND TYPE IN AMPSAC 2.0
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 450.0
FREQUENCY IN HERTZ400.0
MATERIALCASE PLASTIC
TERMINAL TYPE AND QUANTITYCOMPRESSION 6

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
11.000
Unpackaged length
14.000
Unpackaged height
6.000
TOS
B
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
Z
Special requirements – See specific instructions or drawings provided
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
A

Unit pack

PICA SICA
P
Unit pack weight
25.0000
UP SZ MAXB
11.00000
UP SZ MAXL
14.00000
UP SZ MAXH
6.00000
Unit pack cube
0.5340
Supplemental instructions
ZZ = PACKAGING UPDATE REQUIRED

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
24-FEB-1986
NIIN status code
0

Request a quote