Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
265-7702Item number
NIIN 01-265-7702
- Unit price
- $97.31
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 17-OCT-87
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
- FedMall
- Y
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- J
- Source of supply
- SMS
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $97.31
- Quantity per unit pack
- 1
- Controlled inventory item code
- U
- Shelf-life code
- 0
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| NA2P60 | 21810 CHALLENGER ELECTRICAL EQUIPMENT CORP | H | C | 1 | 6 | ZZ | AC | ||
| W-C-375/14 | 81348 FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC | A | 4 | 1 | 3 | TX | 4 | D | |
| WC375/14-009 | 81348 FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC | A | 2 | 2 | 3 | TX | 4 | D | |
| NA2P60 | U4696 E C C SPARES & SERVICES ELECTRO WORKS | H | C | 1 | 6 | ZZ | AC |
Characteristics
| BODY STYLE | |
|---|---|
| BODY LENGTH | INCHES NOMINAL 3.094 |
| BODY WIDTH | INCHES NOMINAL 2.000 |
| BODY HEIGHT | INCHES NOMINAL 2.812 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 1.000 |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| BOSS HEIGHT | INCHES NOMINAL 0.282 |
| POLE QUANTITY | 2 |
| MOUNTING FACILITY TYPE AND QUANTITY | TERMINAL 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES AC 60.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 240.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 10000.0 |
| CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| TRIP RELEASE METHOD | ALL LOCATIONS THERMAL |
| TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS INSTANTANEOUS AND TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 2 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
| INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS SERIES TRIP |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS MAXIMUM AT 200 PCT 120.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
| TRIP RELEASE AMBIENT TEMP RATING | ALL LOCATIONS CELSIUS NOMINAL 40.0 |
| FREQUENCY IN HERTZ | 60.0 |
| MATERIAL | CASE PLASTIC |
| TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81348-W-C-375 |
| TERMINAL TYPE AND QUANTITY | COMPRESSION 2 AND QUICK DISCONNECT, MALE 2 |
| SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81348-W-C-375 TO 14 |
MOE rules
- MOE rule
- DGX1
- MOE CD
- DS
- AMC
- 1
- AMSC
- T
- Date assigned
- 01-NOV-25
- PICA
- GX
- PICA LOA
- 01
- Auth collab
- GX
Freight
- ACTY CD
- TX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- NAPPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 96
- Dt stdzn dec
- 30-DEC-1995
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5925
- Cancelled NIIN
- 5925-00-566-7747
- NIIN status code
- 5
- Effective date
- 02-JUL-2026
- DEMIL code
- A
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.