Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
697-3501Item number
NIIN 01-697-3501
Request a quote
Unit price
$701.58
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
15-SEP-21
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
ESD/EMI code
B
Schedule B export code
8536200040
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DMDSMSEA0.0000$701.581U0Z1-B2---$0.00M
01-OCT-2026DSZSMSEA0.0000$701.581U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
M55629/2-177L81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22EZZ
MIL-PRF-55629/281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ

Characteristics

BODY STYLE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.660 AND INCHES MAXIMUM 1.960
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.719
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.046 AND INCHES MAXIMUM 2.078
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.719 AND INCHES MAXIMUM 0.781
FRAGILITY FACTORMODERATELY RUGGED
END ITEM IDENTIFICATION5840016337831
BOSS HEIGHTINCHES MINIMUM 0.109 AND INCHES MAXIMUM 0.174
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.553
POLE QUANTITY1
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 2.5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS DC 50.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.138
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-55629
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTHREADED STUD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-55629 TO 2

MOE rules

MOE rule
MC49
MOE CD
DM
AMC
1
AMSC
T
Date assigned
01-SEP-21
IMC
Z
IMCA
PA
PICA
GX
PICA LOA
01
SICA
PA
SICA LOA
5D
Auth collab
GX PA

Service data

Marine Corps

SAC
1
MEC
B2

Freight

ACTY CD
PA
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
K3
MIL-PRF-81705, Type III, Class 1, transparent, electrostatic protective, static shielding, barrier material or...
Cush dun
NB
A-A-3129, Type I, Grade B, static dissipative open cell plastic cushioning.
THK
A
1/4 inch thick
Unit cont
E5
ASTM D5118/D5118M, fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
39
ESD sensitive electronic device requirements of MIL-STD-129 apply
Inter cont
E5
ASTM D5118/D5118M, fiberboard box.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
15-SEP-2021
NIIN status code
0

Cancelled and replaced NIINs

FSC
5925
Cancelled NIIN
5925-01-686-9800
NIIN status code
5
Effective date
22-JUL-2026
DEMIL code
A

Request a quote