Catalog item

SWITCH,PRESSURE

5930FSC
00NCB code
593-9295Item number
NIIN 00-593-9295
Request a quote
Unit price
$766.35
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00206
PINC
0000206
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
08-JAN-75
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536509065
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$766.351U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$766.351U0N-------$0.00I

Part numbers

Part number
836T-D451J
CAGE
01121
ROCKWELL AUTOMATION, INC. DBA ROCKWELL AUTOMATION
CAGE status
A
RNCC
3
RNVC
2
Document availability code
E
RNAAC
TX

Characteristics

OVERALL WIDTHINCHES NOMINAL 2.500
PRESSURE SWITCH TYPEDIFFERENTIAL
MOUNTING METHODUNTHREADED HOLE(S)
CONTACT VOLTAGE RATING IN VOLTSFIRST VOLTAGE AC AT SEA LEVEL 120.0
CONTACT VOLTAGE RATING IN VOLTSFOURTH VOLTAGE AC AT SEA LEVEL 600.0
CONTACT VOLTAGE RATING IN VOLTSSECOND VOLTAGE AC AT SEA LEVEL 240.0
OVERALL LENGTHINCHES NOMINAL 3.500
CONTACT VOLTAGE RATING IN VOLTSTHIRD VOLTAGE AC AT SEA LEVEL 480.0
BODY HEIGHTINCHES NOMINAL 3.500
OVERALL HEIGHTINCHES NOMINAL 8.312
INSIDE DIAMETERSINGLE CONNECTION INCHES NOMINAL 0.250
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONDUST RESISTANT AND WATERTIGHT
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERSINCHES NOMINAL 2.719
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERSINCHES NOMINAL 2.719
CONTACT LOAD CURRENT RATINGSECOND VOLTAGE AMPERES RESISTIVE LOAD 3.0
CONTACT LOAD CURRENT RATINGSEVENTH VOLTAGE MILLIAMPERES RESISTIVE LOAD 100.0
NONPILE-UP CONTACT ARRANGEMENTTWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY 1
CONTACT VOLTAGE RATING IN VOLTSSIXTH VOLTAGE DC AT SEA LEVEL 230.0
TERMINAL TYPESCREW
FEATURES PROVIDEDELECTRICAL ACCESS PORT
CONTACT ACTION STIMULUSINCREASE
PROOF PRESSUREPOUNDS PER SQUARE INCH 375.00
NOMINAL THREAD SIZESINGLE PRESSURE CONNECTION INCHES 0.250
MOUNTING FACILITY PATTERNTWO POSITION DIAGONAL
CONTACT ADJUSTABILITYACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGEACTUATION POINT POUNDS PER SQUARE INCH 5.00 TO 40.00
CONTACT LOAD CURRENT RATINGFIRST VOLTAGE AMPERES RESISTIVE LOAD 6.0
PRESSURE CONNECTOR TYPESINGLE CONNECTION PLAIN, THREADED INTERNAL
MEDIA FOR WHICH DESIGNEDGAS OR LIQUID
STYLE DESIGNATOR
THREAD SERIES DESIGNATORSINGLE PRESSURE CONNECTION NPTF
CONTACT VOLTAGE RATING IN VOLTSSEVENTH VOLTAGE DC AT SEA LEVEL 550.0
CONTACT LOAD CURRENT RATINGFOURTH VOLTAGE AMPERES RESISTIVE LOAD 1.2
CONTACT LOAD CURRENT RATINGFIFTH VOLTAGE MILLIAMPERES RESISTIVE LOAD 400.0
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT SCREW
CONTACT VOLTAGE RATING IN VOLTSFIFTH VOLTAGE DC AT SEA LEVEL 115.0
CONTACT LOAD CURRENT RATINGTHIRD VOLTAGE AMPERES RESISTIVE LOAD 1.5
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.266
CONTACT LOAD CURRENT RATINGSIXTH VOLTAGE MILLIAMPERES RESISTIVE LOAD 200.0

MOE rules

MOE rule
FXGX
MOE CD
DF
AMC
3
AMSC
L
Date assigned
01-NOV-05
IMC
Z
IMCA
SX
PICA
GX
PICA LOA
01
SICA
SX
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.