Catalog item

SWITCH,THERMOSTATIC

5930FSC
01NCB code
193-5267Item number
NIIN 01-193-5267
Request a quote
Unit price
$1,240.68
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00451
PINC
0000451
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
05-NOV-84
Precious metals indicator
S
Hazardous material indicator
P
Schedule B export code
9032100000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$1,240.681U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,240.681U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
222-32NL1-22226319278
DETROIT SWITCH INC DBA DETROIT SWITCH INC
A525ZZ
2222631NL-119278
DETROIT SWITCH INC DBA DETROIT SWITCH INC
A525ZZ
222-32NL1-222263119278
DETROIT SWITCH INC DBA DETROIT SWITCH INC
A326TX
63A131712P116331
LOCKHEED MARTIN CORPORATION DIV ROTARY AND MISSION SYSTEMS
A32AZZ

Characteristics

HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONWATERTIGHT AND DUSTPROOF
OVERALL LENGTHINCHES NOMINAL 5.188
OVERALL HEIGHTINCHES NOMINAL 5.687
OVERALL WIDTHINCHES NOMINAL 2.812
BODY HEIGHTINCHES NOMINAL 2.750
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.281
CAPILLARY TUBE LENGTHINCHES NOMINAL 120.0
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERSINCHES NOMINAL 2.406
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERSINCHES NOMINAL 0.656
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERSINCHES NOMINAL 3.281
TEMP SENSING ELEMENT TYPECAPILLARY TUBE
OPERATING TEMP RATINGFAHRENHEIT MAXIMUM 106.0
MOUNTING METHODBRACKET(S) AND UNTHREADED HOLE(S)
FEATURES PROVIDEDELECTRICAL ACCESS PORT
CONTACT ACTION STIMULUSINCREASE
MOUNTING FACILITY PATTERNISOSCELES TRIANGLE
NONPILE-UP CONTACT ARRANGEMENTPOLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION 1
TERMINAL TYPESCREW
CONTACT LOAD CURRENT RATINGFOURTH VOLTAGE AMPERES INDUCTIVE LOAD 2.0
CONTACT LOAD CURRENT RATINGSECOND VOLTAGE AMPERES INDUCTIVE LOAD 3.2
CONTACT LOAD CURRENT RATINGTHIRD VOLTAGE AMPERES INDUCTIVE LOAD 9.6
CONTACT LOAD CURRENT RATINGFIRST VOLTAGE AMPERES INDUCTIVE LOAD 16.0
CONTACT ADJUSTABILITYACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGEACTUATION POINT DEGREES FAHRENHEIT 25.00 TO 90.00
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT SCREW
CONTACT VOLTAGE RATING IN VOLTSFIRST VOLTAGE AC AT SEA LEVEL 115.0
CONTACT VOLTAGE RATING IN VOLTSFOURTH VOLTAGE DC AT SEA LEVEL 550.0
CONTACT VOLTAGE RATING IN VOLTSTHIRD VOLTAGE DC AT SEA LEVEL 115.0
CONTACT VOLTAGE RATING IN VOLTSSECOND VOLTAGE AC AT SEA LEVEL 550.0
SPECIAL FEATURES0.500 IN. NPT MALE UNION INCLUDED
MEDIA FOR WHICH DESIGNEDLIQUID
PRECIOUS MATERIAL AND LOCATIONSILVER CONTACTS
PRECIOUS MATERIALSILVER
STYLE DESIGNATOR

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-MAY-04WP81WP
YB01YB01-SEP-03YB81YB
N9BNDN1C01-JUL-05ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
4.5000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.1250
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
02290

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
05-NOV-1984
NIIN status code
0

Cancelled and replaced NIINs

FSC
5930
Cancelled NIIN
5930-01-186-4309
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote