Catalog item

CONNECTOR,RECEPTACLE,ELECTRICAL

5935FSC
01NCB code
189-3147Item number
NIIN 01-189-3147
Request a quote
Unit price
$107.38
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
15093
PINC
0015093
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
14-SEP-84
Precious metals indicator
G
Hazardous material indicator
P
ESD/EMI code
A
Schedule B export code
8538907080
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$107.381U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$107.381U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSCSADC
4300-01-040-85034595
DYNATECH CO
HC16ZZAC
43000-01-040-85034595
DYNATECH CO
H595TXB
975916-23B150
RAYTHEON COMPANY DBA RAYTHEON CO
A32ATX
975916-249956
RAYTHEON COMPANY DIV CORP
A59ATXB
975916-254X10
RAYTHEON COMPANY
A525ZZ
31-00-00458982
AMPHENOL PCD INC DBA AMPHENOL PCD INC DIV AMPHENOL PCD
A595TXB
42066710158982
AMPHENOL PCD INC DBA AMPHENOL PCD INC DIV AMPHENOL PCD
A525TX
975916-297993
GENERAL DYNAMICS DEFENSE SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
AC16ZZAC

Characteristics

BODY STYLE
OVERALL LENGTHINCHES MAXIMUM 3.950
OVERALL HEIGHTINCHES MINIMUM 1.210 AND INCHES MAXIMUM 1.350
BODY WIDTHINCHES MAXIMUM 0.300
ENVIRONMENTAL PROTECTIONHEAT RESISTANT AND COLD RESISTANT AND THERMAL SHOCK RESISTANT AND SALT WATER RESISTANT AND HUMIDITY RESISTANT AND VIBRATION RESISTANT
MATING END QUANTITY1
CONTACT POSITION ARRANGEMENT STYLE
CONTACT REMOVABILITYSINGLE MATING END SINGLE CONTACT GROUPING NONREMOVABLE
CONTACT MAXIMUM CURRENT RATING IN AMPS3.0
POLARIZATION METHODMATING END
CONNECTOR LOCKING METHODFRICTION
TERMINAL LOCATIONSINGLE MATING END SINGLE CONTACT GROUPING BACK
CONTACT MATERIALSINGLE MATING END SINGLE CONTACT GROUPING COPPER ALLOY 172 OR COPPER ALLOY
CONTACT SURFACE TREATMENTSINGLE MATING END SINGLE CONTACT GROUPING GOLD AND NICKEL
INSERT MATERIALSINGLE MATING END PLASTIC POLYAMIDE NYLON AND GLASS FIBER
CONTACT SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONSINGLE MATING END SINGLE CONTACT GROUPING MIL SPEC 1ST TREATMENT RESPONSE -IL-G-45204 TY 2,GRADE C OR D AND FED SPEC 2ND TREATMENT RESPONSE QQ-N-290 CL 2
TERMINAL TYPESINGLE MATING END SINGLE CONTACT GROUPING WIRE WRAP
CONTACT MATERIAL DOCUMENT AND CLASSIFICATIONSINGLE MATING END SINGLE CONTACT GROUPING FED SPEC SINGLE MATERIAL RESPONSE QQ-C-533 OR FED SPEC SINGLE MATERIAL RESPONSE QQ-B-15 CO- A
INCLUDED CONTACT QUANTITY40
INCLUDED CONTACT TYPESINGLE MATING END SINGLE CONTACT GROUPING LEAF SPRING
PRECIOUS MATERIAL AND LOCATIONGOLD CONTACT SURFACES
PRECIOUS MATERIAL AND WEIGHTGOLD GRAINS, TROY 0.040
PRECIOUS MATERIALGOLD

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
1
AMSC
C
Date assigned
01-NOV-05
IMC
Z
IMCA
HD
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
HD
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061680
NMFC sub
Z
Uniform freight class
34570
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC WIRING PLUGS ETC

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0060
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
93279

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
09-MAR-1999
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.