Catalog item

TERMINAL BOARD

5940FSC
00NCB code
502-8466Item number
NIIN 00-502-8466
Request a quote
Unit price
$25.41
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
00404
PINC
0000404
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
01-JAN-63
Precious metals indicator
A
Hazardous material indicator
N
Schedule B export code
8536908085

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFDSMSEA0.0000$25.411U0NSF9EH-V$0.00F
01-OCT-2026DNDSMSEA0.0000$25.411U09B-----$0.00N
01-OCT-2026DSDSMSEA0.0000$25.411U0N-------$0.00I
01-OCT-2026GPDSMSEA0.0000$25.411U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
9000S6505-73214PC7980064
NAVAL SHIP SYSTEMS COMMAND
A59ACXB
MIL-T-55164-1981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A414ZZ
15TB1081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A224CX3D
564101-7910001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
A59ACXB

Characteristics

CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHINCHES 2.875
BOARD CONSTRUCTIONHOLLOW CONSTRUCTION WITHOUT INSULATED STRIP
MATERIALTERMINALS COPPER ALLOY 670
DISTANCE BETWEEN TERMINAL ROW CENTERSINCHES 0.688
MOUNTING SLOT LENGTHINCHES 0.281
MOUNTING SLOT WIDTHINCHES 0.219
TERMINAL ROW QUANTITY2
CENTER TO CENTER DISTANCE BETWEEN TERMINALSINCHES 0.443
CURRENT RATING IN AMPS30.0
MATERIAL DOCUMENT AND CLASSIFICATIONBOARD MIL SPEC SINGLE MATERIAL RESPONSE -IL---14,TYE -AI-60
MATERIAL DOCUMENT AND CLASSIFICATIONTERMINALS FED SPEC SINGLE MATERIAL RESPONSE QQ-B728,CLASS B
NONFEEDTHRU TERMINAL QUANTITYSINGLE 10
TERMINAL PATTERN ARRANGEMENTMULTI-ROW
TERMINAL DESIGNNONFEEDTHRU
DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLEINCHES 0.719
DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITYINCHES 0.250
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS2.2
BOARD HEIGHT EXCLUDING TERMINALSINCHES 0.625
BASE THICKNESSINCHES 0.375
SPECIAL MARKINGS1 THRU 10
MATERIALBOARD PLASTIC POLYESTER AND GLASS FIBER
BOARD OVERALL WIDTHINCHES 1.438
BOARD OVERALL HEIGHTINCHES 0.812
BOARD OVERALL LENGTHINCHES 3.375
BODY STYLE
MOUNTING FACILITY TYPE AND QUANTITYSLOT 2
NONFEEDTHRU TERMINAL TYPESINGLE 600

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JUN-07WP81WP
YA01YA01-JAN-02YA81YA
YB01YB01-APR-91YB81YB
ZA01ZA01-APR-91ZA81ZA
ZC01ZC01-APR-91ZC81ZC
ZE01ZE01-NOV-98ZE81ZE
ZW01ZW01-NOV-98ZW81ZW
C911GP1G01-AUG-04GX01XG5DXG GXC006
FXGGDF1G01-AUG-04ZSXGX01SX5DGX TUFXCX
N9BGDN1G01-AUG-04ZHDGX01GH5DGXHD GT HX JB KENIGD

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
738
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.2000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0090
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
PACKAGE IAW MIL-T-55164

Packaging instructions

PICA SICA
P
SPI rev
Y
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
CX
Dt stdzn dec
15-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.